Monitor Displays

When using the Monitor Function, a variety of information will appear on the Digital Operator display when each of the U-XX
(display only) parameters is selected.
50
PARAMETER
U -
MONITORED ITEM
01
Frequency reference (Hz)
02
Output frequency (Hz)
03
Output current (A)
04
AC output voltage (V)
05
DC Bus voltage ( VPN )
06
Input terminal status
07
Output Terminal status
08
Motor Torque (%)
(Open loop vector only)
09
Fault record (last 4 faults)
10
Software number
XXXX
11
Output Power (KW)
15
Data reception error
16
PID Feedback (%)
17
PID Input (%)
18
PID Output (%)
DISPLAY
EXAMPLE
60.0
60.0
12.5
230
325
I (1)
I
I
I
II
I
I
(2)
I
I
IIIII
I
72
(3)
oC
0024
99.9
(4)
I
II
I
I
I
II
35.0
100
75.5