CHAPTER 6 TROUBLESHOOTING
M-13
PCI BUS error
Possible cause
Harness
connection
failure
Network board
Main PCB
Step
Check
1
Is the connection between
connector P21 on the main
PCB and connector P1 on the
network board secure?
2
Is the problem solved by
replacing the network board?
3
Is the problem solved by
replacing the main PCB?
Result
No
Reconnect the connectors
securely.
Yes
Replace the network board.
Yes
Replace the main PCB.
6-34
Remedy