enAble40 wheelchair control – installation and programming
Parameter
Actuator 2 Speed 0 – 100 %
Actuator 2 Stop
0 – 12 A
Current
Actuator 2 Stop
3 – 120 s
Time

8.4.11 Lights Menu

Parameter
Allowable
Bulb Voltage
0 – 24 V
Light ½
On/Off
Voltage
Min Light Cur-
0 – 3 A
rent
Indicator ½
On/Off
Voltage
Min Indicator
0 – 3 A
Current
Indicator Time-
0 – 30 s
out

8.4.12 Current Limits Menu

Parameter
Allowable
Peak Current
5 – 75 A
Limit
Peak Current
0 – 60 s
Time
Drive Current
5 – 60 A
Limit
Regen Current
5 – 75 A
Limit
The Powerbase of the enAble40 control unit has three multi-function inputs that can be used
for flexible seat adjustment and speed limit functions.
The speed limits using the multi-function inputs work in the same way as the speed modes;
they create an interpolation between the respective minimum and maximum parameter pairs
of the active profile (Profile 1 or 2). Note that the maximum speed of the power wheelchair is
always the lowest of the respective applicable speed limits. Each of the three multi-function
inputs has its own programme menu.
58 | Ottobock
Allowable
Range
Determines the speed (PWM) of actuator 2.
The driver turns off if the current exceeds this value.
The driver turns off if it runs longer than this period of time.
Range
Determines the voltage of the bulbs. In accordance with the Road
Traffic Licensing Regulations (StVZO), the bulbs are kept at a con-
stant voltage for consistent brightness.
Permits operating the headlights with half of the bulb voltage.
Sets the minimum current for the headlights; an error is recognised
below this current.
Permits operating the direction indicator lights with half of the bulb
voltage.
Sets the minimum current for the direction indicator lights; an error
is recognised below this current.
Sets the maximum time a direction indicator remains active before it
is turned off automatically. A value of 0 deactivates this function.
Range
Delivers a motor current boost. Sets the motor current limit effective
for the Peak Current Time.
Sets the effective time for the Peak Current Limit motor current
limit.
Sets the motor current limit for normal driving.
Sets the motor current limit for regenerative braking.