1-11. List of Error Numbers on the LCD Display

Error numbers are displayed as E-XXXXX (X indicates a number).
Error No.
Description
15030
System error
17001
Abnormality in the Media ID data in
the EEPROM
17002
The image processor block does not start up.
17003
The display block does not start up
17004
The media block does not start up
17005
Abnormality in the start-up process of
the image processor block
17006
Abnormality in the start-up process of
the display block
17007
Abnormality in the start-up process of
the media block
17014
Abnormality in lens communication
17015
Abnormality in the media block
17016
Abnormality in obtaining the lens switch
17017
Internal error in the media block
or
4XXXX
1-16
Service action
Repair the DPR-298 board or replace it.
Rewrite the media ID data in the EEPROM using
"ServiceNavi-EX".
Repair the DPR-298 board or replace it.
Check the connection with the lens unit. If there is
no defect, replace the lens unit.
Repair the DPR-298 or replace it.
Check the connection with the lens unit. If there is
no condition defect, replace the lens unit.
Repair the DPR-298 board or replace it.