Error numbers are displayed as E-XXXXX (X indicates a number).
Error No.
Description
15030
System error
17002
The image processor block does not start up
17003
The display block does not start up
17005
Abnormality in the start-up process of the im-
age processor block
17006
Abnormality in the start-up process of the dis-
play block
17014
Abnormality in lens communication
17016
Abnormality in obtaining the lens switch
MCC-3000MT
Service Action
Repair the DPR-340 board or replace it.
Repair the AVP-18 board or replace it.
Repair the DPR-340 board or replace it.
Repair the AVP-18 board or replace it.
Repair the DPR-340 board or replace it.
Check the connection with the lens unit. If there is no
defect, replace the lens unit.
Check the connection with the lens unit. If there is no
defect, replace the lens unit.