Mitsubishi Electric AG-150A Instruction Book page 15

Air-conditioner control system centralized controller
Hide thumbs Also See for AG-150A:
Table of Contents

Advertisement

3-2-2 Checking the operation condition of groups in different blocks
Click [Block] in the Overview/Floor layout screen to display the operation condition of air conditioner, Ventilator
(LOSSNAY), Air To Water (PWFY) groups, and general equipment for each block.
Use this screen if you want to check data not included in the List screen such as operation mode and set
temperature or if you want to check operation condition for each block.
Batch operation
Click when you want to
perform an operation on all
groups at once.
Update to most recent
condition
Click to update the screen so
that the most recent operation
condition is shown.
Select block
Use this to select which block to
display.
Group icons
These icons are used to indicate
the operation condition of
an air conditioner, LOSSNAY,
Air To Water (PWFY),
or a general equipment group.
Switch to the operation screen
by clicking the icon.
Group name
Group names are displayed.
Item
Overview / Floor
Layout display
Update to most recent
condition
Batch operation
Select block
Group icons
Group name
Operation mode
display
Set temperature
display
Room temperature
display
Weekly schedule
number
Switches to the screen where you can check the operation condition of all the groups or floor
layout.
Click [Update] to ensure the displayed items reflect the most recent operation condition.
When [Auto] is selected, information is updated automatically every minute to reflect the latest
information.
Click [Batch operations] when you want to perform an operation on all groups in the block at
once.
Use this to select which block to display and perform operations on.
The operation condition is indicated by the icon that is displayed. To switch to the operation
screen, click on the icon.
Group names are displayed.
The operation mode is displayed.
The set temperature is displayed.
Note: The water temperature setting will be displayed for the Air To Water (PWFY) group.
Note: Depending on the model, temperatures will be displayed in 0.5°C or 1°C increments.
The temperature of the indoor unit's intake is displayed.
Note: Dispay/Non-display of the room temperature can be selected on the initial setting
browser.
Note: Because the temperature displayed here is of the indoor unit's intake, it could be
different from the actual room temperature.
Note: The set temperature and room temperature will not be displayed for the Ventilator
(LOSSNAY) group.
Note: The operation mode, set temperature, and room temperature will not be displayed for
the general equipment group.
Note: The current water temperature will be displayed for the Air To Water (PWFY) group.
Note: The temperature display can be set to display in either Celsius (°C) or Fahrenheit
(°F).
Note: Depending on the model, temperatures will be displayed in 0.5°C or 1°C increments.
Indicates the weekly schedule that is currently effective.
"Weekly * in period"
Note: The schedule number (1 through 5) that is currently effective is displayed in " * ".
Description
15
Overview/Floor Layout
display
Click to display operation
condition of groups in
Overview or Floor layout
display.
Weekly schedule
number
Indicates the weekly
schedule number that is
currently effective.
Set temperature display
The set temperature is
displayed here.
Room temperature
display
The temperature of the
indoor unit's intake is
displayed here.
Operation mode display
The operation mode is
displayed here.