Troubleshooting - ADJ COB Cannon Wash DW User Instructions

Hide thumbs Also See for COB Cannon Wash DW:
Table of Contents

Advertisement

COB Cannon Wash DW
The COB Cannon Wash DW comes with a 80 degree lens already
attached. Included in the box are optional 40 & 50 degree lenses.
To switch lenses simply remove the retainer ring located in front
front of the current lens. After the retainer ring has been removed
carefully remove the lens, and attach your desired lens. Reinstall
the retainer ring and the switch is complete. When reinstalling the
retainer ring, make sure to insert 3 points of the retainer ring into
the 3 notches located around the inside of the lens frame.
COB Cannon Wash DW
Ramp Effect
Standard
Stage
TV
Architectural
Theatre
ADJ Products, LLC - www.adj.com - COB Cannon Wash DW User Manual Page 18
Optional Lens Change
Dimmer Curve Chart
(Fade Time)
(Fade Time)
COB Cannon Wash DW
With this feature you can connect the fixtures to one another
using the PowerCON input and output sockets. The quantity that
can be connected is 5 fixtures maximum. After 5 fixtures you will
need to use a new power outlet. They must be the same fixtures.
DO NOT mix fixtures.
COB Cannon Wash DW
Disconnect the unit from its power source. Remove the power cord
from the unit. Once the cord has been removed, the fuse holder is
located under the powerCON connection. Use a phillips head screw-
driver to remove the fuse holder. Remove the fuse located inside the
fuse holder and replace with the new fuse. Install the fuse holder and
new fuse and secure it.
COB Cannon Wash DW
Listed below are a few common problems the user may encounter,
with solutions.
Unit not responding to DMX:
1. Check that the DMX cables are connected properly and are
wired correctly (pin 3 is "hot"; on some other DMX devices
pin 2 may be 'hot'). Also, check that all cables are connected
to the right connectors; it does matter which way the inputs
and outputs are connected.
Unit does not respond to sound:
1. Quiet or high pitched sounds will not activate the unit.
2. Make sure that Sound Active mode is activated.
COB Cannon Wash DW
Due to fog residue, smoke, and dust cleaning the internal and exter-
nal optical lenses must be carried out periodically to optimize light
output.
1. Use normal glass cleaner and a soft cloth to wipe down the
outside casing.
2. Clean the external optics with glass cleaner and a soft cloth
every 20 days.
3. Always be sure to dry all parts completely before plugging
the unit back in.
Cleaning frequency depends on the environment in which the fixture
operates (i.e. smoke, fog residue, dust, dew).
ADJ Products, LLC - www.adj.com - COB Cannon Wash DW User Manual Page 19