2.
SPECIFICATIONS
2-1.
COMPACT CASSETTE TYPE
Model name
Power source
Available voltage range
Cooling Rated
Capacity
Heating Rated
Moisture removal
Power consumption
Running current
Cooling
Airflow
rate
Fan
Heating
Fan Type × Q'ty
Fan Motor Output
Cooling
Sound pressure level
Heating
Dimension (H×W×D)
Fin pitch
Heat
exchanger
Rows × Stages
Pipe type
Fin Type
Material
Enclosure
Color
Unit
Net
Panel
Dimensions
( H×W×D )
Unit
Gross
Panel
Unit
Net
Panel
Weight
Unit
Gross
Panel
Liquid
Size
Connection
Gas
pipe
Method
Material
Drain pipe
size
Cooling
Operation range
Heating
Remote controller type
Note : Specifications are based on the following conditions.
Power source of specifications : 230V
Cooling : Indoor temperature of 80°F(26.7°C)DB/67°F(19.4°C)WB,and outdoor temperature of 95.0°F(35°C)DB/75°F(23.9°C)WB.
Heating : Indoor temperature of 70°F(21.1°C)DB/60°F(15.6°C)WB,and outdoor temperature of 47°F(8.3°C)DB/43°F(6.1°C)WB.
Pipe length : 16.4ft.(5m) [Outdoor unit - Branch box], 9.8ft. (3m) [Branch box - Indoor unit]
Height difference : 0 ft.(0m) [Outdoor unit - Indoor unit].
AUU9RLF
Btu/h
9,000
kW
2.64
Btu/h
10,200
kW
3.00
pints/h(l/h)
2.5 (1.2)
W
18
A
0.15
High
318 (540)
Med
288 (490)
Low
259 (440)
Quiet
230 (390)
CFM
3
(m
/h)
High
318 (540)
Med
288 (490)
Low
259 (440)
Quiet
230 (390)
W
42
High
33
Med
31
Low
29
Quiet
27
dB(A)
High
34
Med
32
Low
29
Quiet
27
in. (mm)
FPI
in.(mm)
lb. (kg)
in.(mm)
in.
°F (°C)
%RH
°F (°C)
- (04 - 05) -
AUU12RLF
1ø 208/230V 60Hz
187-264V
12,000
3.51
13,500
3.96
3.2 (1.5)
23
0.19
359 (610)
312 (530)
277 (470)
241 (410)
359 (610)
312 (530)
277 (470)
241 (410)
Turbo × 1
42
37
33
31
28
37
33
31
28
8-9/32 × 51-9/16 × 17/32 + 8-9/32 × 49-7/32 × 17/32
(210×1310×13.3 + 210×1250×13.3)
21
2×10
Copper tube
Aluminium
PS
White
(Approximate color of Mansell N9.25 /)
9-21/32 × 22-7/16 × 22-7/16 (245×570×570)
1-15/16 × 27-9/16 × 27-9/16 (49 × 700 × 700)
10-7/16 × 28-3/4 × 24-19/32 (265×730×625)
4-23/32 × 30-1/8 × 29-23/32 (120 × 765 × 755)
33 (15)
5.7(2.6)
40 (18)
10(4.5)
1/4 (6.35)
3/8 (9.52)
Flare
HARD PVC
Outer Diameter : 1-1/16
Inner Diameter : 3/4
64 to 90 (18 to 32)
80 or less
60 to 88 (16 to 31)
Wired [Wireless(option)]
AUU18RLF
18,000
5.28
20,000
5.85
4.2 (2.0)
39
0.30
441 (750)
359 (610)
306 (520)
241 (410)
471 (800)
418 (710)
353 (600)
265 (450)
42
42
37
33
29
44
40
37
30
1/2 (12.7)