Multi Zone Specification
ARU9RML
Multizone Wall Mount
Job Name:_______________________________
Location: ________________________________
Engineer:________________________________
Submitted to: _____________________________
Submitted by:_____________________________
Power
Fan type
No. Motors
CFM [.10 in.WG]
Sound Pressure Level
db (Hi,Me,Lo,Qu)
F.L. A.
Refrigerant
O.D. Discharge
O.D. Suction
Dimensions
Uncrated
Crated
Weight
Net
Gross Shipping
Fujitsu General America, Inc.
Fairfield, NJ 07004
Toll Free: 1-888-888-3424
Fax: (973) 836-0447
www.fujitsugeneral.com
V/Hz/P
(W)
(Hi,Me,Lo,Qu)
383/353/324/283
(A)
in (mm)
in (mm)
(in)
7-25/32 × 27-9/16 × 24-13/32
(mm)
(198 × 700 × 620)
(in)
10-7/8 × 38-1/8 × 29-3/4
(mm)
(276 x 968 × 756)
lbs. (kg)
lbs. (kg)
Note:
Specifications are based on the following conditions.
Power source of specifications : 230V
Cooling: Indoor temperature of 80°F(26.67°C)DB / 67°F(19.44°C)WB, and outdoor temperature of 95°F(35°C)DB/75°F(23.89°C)WB.
Heating: Indoor temperature of 70°F(21.11°C)DB / 60°F(15.56°C)WB, and outdoor temperature of 47°F(8.33°C)DB/43°F(6.11°C)WB.
Standard Static Pressure: 0.10in.WG (25Pa)
Pipe length : 16.4ft. (5m) [Outdoor unit - Branch box], 9.8ft. (3m) [Branch box - Indoor unit]
Height difference : 0 ft.(0m) [Outdoor unit - Indoor unit]
Fujitsu products are subject to continuous improvements. Fujitsu reserves the right to modify product design, specifications and
information in this data sheet without notice and without incuring any obligations.
Approval:__________________Date:_________
Construction: ____________________________
Unit #:__________________________________
Drawing #:_______________________________
Reference:_______________________________
Cooling Capacity
230/60/1
Moisture Removal
Sirocco
2 (81)
Heating Capacity
Temperature Setting Range
29/28/27/26
.37
Cooling
410A
Heating
Ø1/4" (6.35)
Drain Pipe Size**
Ø3/8" (9.52)
H x W x D
Remote Control Type
Electrical Connection*
*Power and communication are fed from the outdoor unit.
**Adapter to 3/4" PVC included with unit.
41 (19)
55 (25)
(BTU/h)
pt/h (l/h)
(BTU/h)
_____________13,500
°F(°C)
64~90 (18~32)
°F(°C)
60~88 (16~31)
OD in
ID in
____________
AWG
14/3 with ground
12,000
3.8 (1.8)
Ø1-1/16
Ø3/4
Wired
Need help?
Do you have a question about the ARU12RLF and is the answer not in the manual?
Questions and answers
Mon unité ne fonctionne plus à cause probablement de l'accumulation de neige des dernières tempêtes et les clignotents OPERATION,TIMER et Economy n'arrêtent pas de clignoter
When the OPERATION, TIMER, and Economy lights are flashing on a Fujitsu ARU12RLF unit after snow accumulation, it likely indicates an error condition. Specifically, it may be caused by an outdoor thermistor error due to snow affecting the outdoor unit. This can happen if the outdoor temperature thermistor is open or short-circuited, which may be caused by:
1. Connector connection failure
2. Thermistor failure
3. Main PCB failure
Check the thermistor connections, ensure cables are not damaged or disconnected, and measure the thermistor resistance to verify functionality. Reset the power after correcting any connection issues.
This answer is automatically generated