4. Leak Detection Icon Flashing
Most leaks will be detected by either the internal leak detection system that will trigger an alarm, or will
trip the Waterlogic block located in the installation kit.
1. Turn off both the Green Heater/Compressor Switch and Red Power Switch. O = OFF
2. Unplug unit.
3. Remove Top Cover.
4. Remove Right Side Panel (Left Side Panel if standing behind unit).
5. Dry inside of the CUBE.
6. Replace Top Cover (leave Side Panel off).
7. Connect power cord.
8. Turn on Red Power Switch I = ON
9. Dispense water and check for leak.
10. Once leak is located, correct issue.
11. Remove Top Cover.
12. Replace Side Panel.
13. Replace Top Cover.
14. Turn on Green Heater/Compressor Switch. I = ON