WARNING!
HOT WATER. Unit produces Hot Water in excess of 87
(125
o
F) can cause severe burns or scalding. Keep unauthorized people and children away from the
unit to avoid accidental dispensing of hot water.
WARNING!
CONNECT TO POTABLE WATER SUPPLY. This system is to be used for water only and is
not intended for use where water is microbiologically unsafe or with water of unknown quality
without adequate disinfection. System is designed for the supplemental bactericidal treatment of
public drinking water, or other drinking water, which has been tested and deemed acceptable for
human consumption by the state or local health agency having jurisdiction. The system is designed to
reduce normally occurring non-pathogenic or nuisance microorganisms only. System is not intended
for treatment of contaminated water.
WARNING!
STORE AND TRANSPORT UNIT EMPTY. ALWAYS SANITIZE BEFORE USE.
The unit must be completely drained and sealed before storing to avoid stagnation and reduce
microbiological contamination (potential bacterial growth). Sanitize before use to eliminate any
potential microbiological contaminates
CAUTION!
INDOOR USE ONLY. Intended for household use only. Never expose to direct sunlight,
heat sources, or ambient air temperature above 37°C (100°F) or below 2°C (35°F). Install indoors and
keep unit away from excessive humidity. Never expose to freezing temperatures. Ensure there is
adequate clearance around the unit to allow refrigeration system condenser to dissipate heat.
Warmer environments require more clearance around the unit. Minimum clearance around all
surfaces of the machine is 2-inches. Installs where the ambient temperature exceeds 27°C (80°F),
require a minimum of 4-inches clearance for proper heat dissipation and efficient operation.
CAUTION!
USE A WATER PRESSURE REGULATOR. Waterlogic will not be responsible for injury or
damage caused by excessive water pressure. Input or feed pressure must be 40 psi to 60 psi. Be
aware of any potential pressure surges caused by building/municipal pumping stations. Water block
devices and external leak detectors are strongly recommended. Locate the unit as close to the water
supply and the electrical connections as possible to minimize risk.
CAUTION!
USE PROPER SUPPLY LINES AND FEED WITH POTABLE AMBIENT WATER ONLY.
Feed water over 37°C (100°F) may damage the treatment components. Always use supply lines with
adequate pressure rating and UV resistance. Close water supply valve and contact service
representative if a leak is noticed.
Contact Waterlogic for assistance or help finding an Authorized Service Representative.
CUBE Manual