Pre-Installation Procedures - WaterLogic CUBE FIREWALL Manual

Table of Contents

Advertisement

DANGER!
ELECTRICAL SHOCK HAZARD.
Only qualified personnel who have read and understand this entire manual should attempt to install,
or service this unit, failure to do so could result in death or serious injury. DO NOT plug into an
electrical supply until specifically instructed.
WARNING!
Read and understand the contents of this manual before attempting to service CUBE
Water Treatment System. Failure to follow the instructions in this manual could result in death,
serious personal injury, or severe property damage. Only trained and qualified technicians should
attempt to install, maintain, or service Waterlogic Equipment.
WARNING!
ALWAYS SANITIZE BEFORE USE.
Sanitize before use to eliminate any potential microbiological contaminates.
Materials Needed:
• Personal Protective Equipment. Rubber or Nitrile Safety Gloves and Protective Eyewear
• Phillips Screwdriver
• Temperature Gauge
• Water Pitcher or Container to collect water from the faucet
• 5-gallon container or drain basin
• Sanitizer - Household Bleach (5.25% Sodium Hypochlorite) or Citric Acid Based Cleaner
• ¼" Plastic Tubing, at least 4 feet in length, and assorted ¼" quick connect fittings.
• TDS Meter and Test Strips for measuring chlorine. - Optional
• 1/8 NPT Female Thread to ¼" Compression Fitting (Used to connect hose to drain fittings)
1. Unpack the Waterlogic Cube Water Treatment System and check exterior for damage.
Flush Filters
CAUTION!
FILTER FLUSH REQUIRED.
The CUBE Water Treatment Systems are supplied with a filter. In order for our filters to perform as
represented and to provide the best quality water possible, it is essential that filters be replaced
periodically. The frequency of filter changes depends upon your water quality and your water usage.
For example, if there is a lot of sediment and/or particles in your water, then you will have to change
your filters more frequently than a location with little to no sediment. Be sure to replace your filters
whenever you notice a decline in the performance, whether it is a drop-in flow rate and/or pressure
or an unusual taste in the water.
2. Select Ambient Water Selection + Dispensing Button. Dispense approximately 10 liters of water to
remove the excess carbon fines and generate the filter.
NOTE:
Filters should not be flushed prior to 24 hours before installation to limit Microbial Growth.
CUBE Manual

PRE-INSTALLATION PROCEDURES

Page 49 - Revision: 5-24-2017

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents