1.5
Power Requirements
1.5.1
System power
Minimum power input: DC12V (-25%) -30V (+20%), Absolute Maximum Ratings
Voltage is 9V - 36V
1.5.2
RTC battery
BR2032 3 V/190 mAh
1.6
Environment Specification
1.6.1
Operating temperature
-10 ~ 60 °C with 0.7m
1.6.2
System safety certification test temperature
0 ~ 40 °C with 2.5" HDD
1.6.3
Relative humidity
95% @ 40 °C (non-condensing)
1.6.4
Storage temperature
-40 ~ 85 °C (-40 ~ 185 °F)
1.6.5
Vibration during operation
When system is equipped with SSD only: 3 Grms, IEC 60068-2-64, random, 5 ~
500 Hz, 1 Oct/min., 1 hr/axis, x,y,z 3 axes.
When system is equipped with 2.5-inch HDD: 0.5 Grms, IEC 60068-2-64, ran-
dom, 5 ~ 500 Hz, 1 Oct/min., 1 hr/axis, x,y,z 3 axes.
1.6.6
Shock during operation
When system is equipped with SSD only: 20 G, IEC 60068-2-27, half sine, 11
ms duration.
1.6.7
Safety
CCC, UL
1.6.8
EMC
CE, FCC, CCC, BSMI