DDTs Issue
CSCdy22633
CSCdy24461
CSCdy24461
CSCdy31818
OL-2914-01 Rev D0, July 3, 2003
Severity 2 Open Caveats for MGX 8850 3.0.10 Software (continued)
Description
Hardware: axsm1b_oc3
Symptom: Only on a specific node, and only on a specific slot pair, does the dspcons
and dspcons -filt 4 command give syntax error usage information even though the
command was correctly entered. Commands provide expected output on other slots
in the node, and in the same slots in different nodes, the problem is not seen. Also
there is also an error message logged for slot 11 every time the command "dspcons
-filt 4" is issued, "cliCallXfunc: xFunc() Parameter validation failed non MIB-based
command:".
Conditions: The dspcons command with the filter option had failed due to the
presence of connections on a port that did not exist. This could have been caused by
two possible scenario: a) the port had disappeared off the port database, b) the
connections were "dangling" connections that did not get cleaned up as part of a
delete operation. Most of the clues found in the logs point to the latter.
Workaround: The problem is not malignant and does not impact the normal
functioning of the switch, a) It does not impact traffic, b) provisioning operation on
the node should be possible, c) the port can be re-added if necessary and connections
can be provisioned on the port. The only connections that cannot be re-added are
those which are dangling in the database. d) The only impact of the dangling
connections is that it reduces the number of connections that can be provisioned in
the card. The problem can be rectified by deleting the dangling connections on the
card.
Hardware: axsm1b_oc3
Symptom: Spurious alarms being reported on AXSM line interface.
Conditions: Unknown.
Workaround: Unknown.
Hardware:axsm1b_oc3
Symptom: Spurious alarms being reported on AXSM line interface.
Condition: Unknown.
Workaround: Unknown.
Hardware: pxm45b
Symptom: Getting error message on RPM "% Transmit to PXM Timed out" while
executing a few commands on the RPM. Show log in the RPM displays the following
message: 00:01:46: rpmrscprtn: Partition VCC:part(0):cntlr(0) Out-Of-Synch
(OnlyOnPXM) RPM [(slot=0 ifnum=0 part=0 cntlr=0 status=6): ingr:0 0 egr:0 0
vpi:0 0 vci:0 0 chans:0 0] PXM [(slot=0 ifnum=1 part=0 cntlr=0 status=0): ingr:0 0
egr:0 0 vpi:0 0 vci:0 0 chans:0 0]
Conditions: An AXSM was inserted in place of an RPM. When the RPM was inserted
back, some commands were timing out on the RPM with the error message "%
Transmit to PXM Timed out"
Workaround: None.