Download Print this page

Beretta MySmart 28 C.S.I. Installer And User Manual page 17

Hide thumbs Also See for MySmart 28 C.S.I.:

Advertisement

Available languages

Available languages

IMPORTANT
If the 3 (5 metres) or 4 (4 metres) curves are set the bypass must
be replaced with the one supplied, following the procedure indicated
below:
Remove boiler electrical power by setting the system's main switch
to off.
Close the system taps and empty the boiler heating circuit.
Extract the bypass body cover fixing spring (D).
Extract the bypass body cover (E).
Replace the bypass valve (F) with the one included.
Refit the bypass body cover and its spring.
D
F
E
6 METRES DISCHARGE HEAD
600
550
500
450
400
350
300
250
200
150
100
50
0
0
100
200
300
400
System capacity [l/h]
7 METRES DISCHARGE HEAD
700
650
600
550
500
450
400
350
300
250
200
150
100
50
0
0
100
200
300
400
System capacity [l/h]
Modulation area
500
600
700
800
900
1000
Modulation area
500
600
700
800
900
1000
1100
Eventual releasing of the circulator shaft
Insert a screwdriver in the hole (1) of the circulator
Press (a) and turn the screwdriver (b) until the release of the
crankshaft.
Perform this operation with extreme caution to avoid damag-
ing the components.
500
450
400
350
300
250
200
150
100
50
0
0
100
200
1100
1200
400
350
300
250
200
150
100
50
0
0
100
200
1200
1300
a
1
5 METRES DISCHARGE HEAD
Modulation area
300
400
500
600
700
800
System capacity [l/h]
4 METRES DISCHARGE HEAD
Modulation area
300
400
500
600
700
System capacity [l/h]
MySMART C.S.I.
b
900
1000
1100
1200
800
900
1000
17

Advertisement

loading