Download Print this page

Beretta MySmart 28 C.S.I. Installer And User Manual page 14

Hide thumbs Also See for MySmart 28 C.S.I.:

Advertisement

Available languages

Available languages

ENGLISH
- Press the "combustion analysis" button a third time to reach the num-
ber of revolutions that corresponds to the minimum output (table 2).
- Check the CO
value: (table 5) if the value does not comply with the
2
indications in the table act on the gas valve min adjustment screw
(fig. 46).
- To exit the "combustion analysis" function turn the command knob.
- Extract the gases analysis probe and refit the plug.
- Close the instrument panel and reassemble the shell.
The "combustion analysis" function automatically deactivates if the
card generates an alarm. In the event of a fault during the combustion
analysis phase, carry out the reset procedure, acting on the mode se-
lector as described in section 4.4.
Table 1
Maximum domestic hot
water fan rotations
28 C.S.I.
Table 2
Minimum number of fan
rotations
28 C.S.I.
Table 2a
Minimum number of fan
rotations in case of collective
smoke pipes under pressure
28 C.S.I.
Table 3
Maximum number of
heating fan rotations
28 C.S.I.
Table 4
Max CO
2
28 C.S.I.
Table 5
Min CO
2
28 C.S.I.
Table 6
Slow ignition
28 C.S.I.
4.8
Gas conversion (fig. 47)
It is easy to transform gas from o
family even with the boiler installed.
This job must be done by professionally qualifi ed personnel only.
The boiler is supplied to run on natural gas (G20) – see the product
rating plate for details.
The boiler can be transformed to use propane gas using a special kit.
Follow the instructions given here below for disassembly:
- Switch off the power to the boiler and turn off the gas cock.
- Remove the panel and casing.
- Lift up and rotate the instrument panel.
- Open the air box cover.
- Unscrew the screws fastening the silencer (A) and remove it.
- Disconnect the mixer gas ramp. Unscrew the clamp screws and
relative mixer springs to fan and then remove it.
- Loosen the plastic Venturi (B) by levering from under the teeth (BE
CAREFUL NOT TO FORCE THEM) and press from the opposite
side until it is completely extracted from the aluminium shell.
- Replace the plastic Venturi with the one contained in the kit.
- Reassemble the mixer with the fl ap in a horizontal position and
the spacer springs placed at 120° as shown in the fi gure.
- Reassemble gas ramp working vice versa.
- Switch on the power to the boiler and turn on gas cock again.
- Check the number of times the fan turns.
- Fill in and stick on the accompanying transformation data label.
- Close the air box cover.
- Close up the instrument panel again.
- Reassemble the casing and panel.
Programme the "Gas type" parameter and regulate the boiler fol-
lowing the instructions in the "Adjustments" section.
Transformation must be done by qualifi ed personnel only.
14
Methane
Liquid gas
gas (G20)
(G31)
61
61
M e t h a n e
Liquid gas
gas (G20)
(G31)
12
15
Methane
Liquid gas
gas (G20)
(G31)
18
19
Methane
Liquid gas
gas (G20)
(G31)
45
45
Methane
Liquid gas
gas (G20)
(G31)
9.0
10.0
%
Methane
Liquid gas
gas (G20)
(G31)
9.0
10.0
Methane
Liquid gas
gas (G20)
(G31)
33
33
ne family to gas belonging to another
After completing transformation, regulate the boiler again
following instructions given in the specifi c paragraph and
apply the new identifi cation label from the kit.
Check that fl ap and Clapet are working correctly (all open
at rated fl ow, all closed at minimum fl ow)
RANGE RATED
This boiler can be adapted to the heating requirements of the system,
in fact it is possible to set the maximum delivery for heating operation
of the boiler itself:
- switch off the power supply
- setting the heating water temperature selector at the maximum value
- remove the shell
- turning the instrument panel towards you
- unscrew the two screws of the small cover on the electronic board to
have access to the terminals
- insert JP1 jumper
- power up the boiler.
rpm
The display shows "ADJ" for about 4 sec.: it is then possible to change
the maximum heating value by means of the heating water temperature
selector and the CO button in order to set and confirm the desired
value.
The icon
will appear on the display.
rpm
Finish the procedure by removing the jumper JP1 to store the set
values.
Once the desired output (maximum heating) has been set, note the
value on the table on the back cover.
For subsequent controls and adjustments, refer to the set value.
The calibration does not entail the ignition of the boiler. By rota-
ting the heating setpoint selector knob, the value expressed in
g/min
hundreds (e.g. 25 = 2500 rpm) is automatically displayed.
The boiler is supplied with the adjustments shown in the table.
Depending on plant engineering requirements or regional flue gas
emission limits it is, however, possible to modify this value, referring
rpm
to the graphs.
240
230
220
210
200
190
180
%
170
160
150
140
130
120
110
100
%
90
80
70
60
50
40
30
20
10
0
2
4
6
6400
6000
5600
5200
4800
4400
4000
3600
3200
2800
2400
2000
1600
1200
800
2
4
6
HTG curve (Qnheating)
8
10
12
14
16
18
20
Heat output (kW)
CO s.a. curve (Qnheating)
8
10
12
14
16
18
20
Heat output (kW)
22
24
26
28
30
22
24
26
28
30

Advertisement

loading