8.4. Simple Comparison Normal Batching

When the weight value is compared with the setpoint and the condition is met, the control output turns OFF.
Weight value  Near-zero (Sq F-25)
Weight value  Final - Optional preliminary
Weight value  Final - Preliminary
Weight value  Final - Free fall
Weight value > Final - Underweight
Weight value > Final + Overweight
Final + Overweight  Weight value  Final - Underweight

8.5. Simple Comparison Loss-in-weight Batching

When the weight value is compared with the setpoint and the condition is met, the control output turns OFF.
Weight value  Near-zero (Sq F-25)
Gross value  Full
–Weight value  Final - Preliminary
–Weight value  Final - Free fall
–Weight value < Final - Underweight
–Weight value > Final + Overweight
Final + Overweight  -Weight value  Final - Underweight

8.6. Simple Comparison Functions

●Automatic print
When the –weight value is five times the minimum division or more and the large flow, medium flow and
small flow outputs turn ON, data is output once from the standard serial output or options. To output again,
wait for the –weight value to be four times the minimum division or less.
Condition
Condition
Page 25
Control output
Near-zero
Large flow
Medium flow
Small flow
Underweight
Overweight
OK
Control output
Near-zero
Full
Medium flow
Small flow
Underweight
Overweight
OK