Installing the PTT motor
When assembling the PTT unit, do not use
a rag. Otherwise, dust and particles could
get on the PTT unit components, causing
poor performance.
1. Install the joint "1".
Make sure that the deeper end of the
groove "a" is facing the PTT motor when
installing the joint "1".
a
2. Install a new O-ring "1" and the PTT
motor assembly "2", and then tighten the
PTT motor mounting bolts "3" to the
specified torque.
TIP:
Align the protrusion "a" on the armature shaft
with the slot "b" in the joint.
3
2
3
PTT motor mounting bolt "3":
7 N·m (0.7 kgf·m, 5.2 ft·lb)
Installing the reservoir
1. Install a new O-ring "1", the filter "2", and
the circlip "3".
1
a
1
b
2. Install a new O-ring "1" and the reservoir
"2", and then tighten the reservoir mount-
ing bolts "3" to the specified torque.
3. Install a new O-ring "4" to the reservoir
cap "5", and then install the reservoir cap
"5".
4. Tighten the reservoir cap "5" to the speci-
fied torque.
Reservoir mounting bolt "3":
7 N·m (0.7 kgf·m, 5.2 ft·lb)
Reservoir cap "5":
7 N·m (0.7 kgf·m, 5.2 ft·lb)
9-53
PTT motor
3
2
1
2
3
1
3
4
5