Errors - Buffalo TeraStation 5010 User Manual

Network attached storage
Hide thumbs Also See for TeraStation 5010:
Table of Contents

Advertisement

LCD Message
Date Time
Date and Time
YYYY/MM/DD
hh:mm
LANx DHCP
192.168.11.150
IP Address
LAN2
Port Trunking

Errors

LCD Message
Invalid Firmware
E10 UPS Running Off
Battery
E11 Fan Failure
E12 Cooling Failure
E14 Can't Mount
Array x
E16 Drive x Not
Found
E22 Can't Mount
Drive x
Description
Displays the date and time set in the
TeraStation.
Displays the IP address. If acquiring from a
DHCP server automatically, "DHCP" will be
displayed. If configuring a static IP address,
"Static IP" will be displayed.
Displays if port trunking is configured.
Description
The firmware is corrupted and the
TeraStation boots in emergency mode.
The TeraStation is running on the UPS
battery due to a power outage.
If the setting to use the UPS connected to
this TeraStation has been configured, the
UPS cable may be disconnected.
If the setting to use the UPS connected to
another TeraStation on the same network
has been configured, the LAN cable of this
TeraStation may be disconnected.
An error occurred in the fan speed.
A rise in the system temperature may have
exceeded the allowable safety value.
RAID array x cannot be mounted.
Unable to find drive x.
Unable to mount drive x.
Corrective Action
Update the TeraStation firmware to recover
from emergency mode by following the
procedure in the "Booting the TeraStation
in Emergency Mode" section above. If the
error is displayed again, contact Buffalo
technical support for assistance.
Shut down the TeraStation safely and wait
until the power outage ends. If certain
settings are configured, the TeraStation
may shut down automatically when the
error is detected.
Verify that the UPS cable or LAN cable is
connected properly.
Check that no foreign objects or dust are
clogging the fan. If any foreign objects or
dust are found, use a pair of tweezers, air
duster, or other tool to remove them. If the
error is displayed again, contact Buffalo
technical support for assistance.
Do not place objects in the area around
the TeraStation. Also, move the TeraStation
to a cool location.
Run the RAID array disk check in Settings.
Drive x may be disconnected or may have
failed. After shutting down, reinstall the
drive.
Format the drive. After formatting, if the
error still appears after rebooting, replace
the drive. If the error is displayed again,
contact Buffalo technical support for
assistance.
167
Corrective Action
-
-
-