Buffalo TeraStation 5010 User Manual page 82

Network attached storage
Hide thumbs Also See for TeraStation 5010:
Table of Contents

Advertisement

4
Select a TeraStation to be the backup destination device and enter its administrator username and password
(the username is "admin", the password is "password" by default).
5
Select the LAN port to be used for sharing files and enter a virtual IP address and subnet mask.
About Virtual IP Address:
A virtual IP address is an IP address that will be used for file sharing while failover is configured. By assigning
a different IP address from the one to be assigned to the LAN port, you can access the TeraStation for sharing
files, as well as open Settings using the virtual IP address. This IP address will be inherited to the backup
TeraStation when failover occurs, so you can access the backup TeraStation even if you don't know the backup
TeraStation's static IP address.
Configure an unused IP address for the virtual IP; make sure it uses the same segment as the main and backup
TeraStations.
6
Select the LAN port to be used for transferring data via failover, then click Continue.
7
If the administrator username and password is correct, the backup TeraStation will beep. Press and hold the
function button to accept the settings from the main TeraStation. When you press the function button, the
backup TeraStation will stop beeping. Hold it down until the backup TeraStation beeps again.
8
The I51 message will display on the LCD panel and NAS Navigator2 for both TeraStations. Wait until
initialization finishes. Failover is configured after it finishes and the I51 message disappears.
Notes:
• If replication is configured for more than one folder, initialize the TeraStation before configuring failover.
• The main TeraStation cannot be used as the backup location for Time Machine.
• Do not use the same TeraStation for both failover and replication, or failover and Time Machine.
• If email notification is enabled and failover occurs, navigate to Management - Email Notification - Edit in the
main TeraStation's Settings and click OK.
• Ethernet frame size settings for main and backup TeraStations should be 1500 bytes. To change the Ethernet
frame size, navigate to Network - IP Address - Edit, and change the Ethernet frame size to "1500" bytes.
• Files whose filenames contain more than 80 alphanumeric characters will not be backed up.
• If the I33 error message appears on the LCD panel, navigate to Backup - Replication and click Resync.