Error Messages; Mains Reset; Brief Description - Hettich UNIVERSAL 320 R Repair Instructions

Hide thumbs Also See for UNIVERSAL 320 R:
Table of Contents

Advertisement

5

Error messages

5.1

MAINS RESET

• Switch off the mains switch.
• Wait at least for 10 seconds and then switch on the mains switch again.
5.2

Brief description

Error designation
TACHO-ERROR
TACHO-ERROR
IMBALANCE
CONTROL-ERROR
N > MAX
CONTROL-ERROR
CONTROL-ERROR
ROTORCODE
ROTORCODE
ROTORCODE
MAINS INTERRUPT
N < MIN
CONTROL-ERROR
CONTROL-ERROR
CONTROL-ERROR
CONTROL-ERROR
CONTROL-ERROR
CONTROL-ERROR
SER I/O-ERROR
SER I/O-ERROR
SER I/O-ERROR
SER I/O-ERROR
* Error number will not be displayed
10/66
No. Brief description
1
Speed sensor on top of the motor: Speedometer
pulses break down during rotation
2
No speedometer pulses after start command
(3)* Imbalance on motor axle
4
Lid lock error: lid opened without recognizing
rotor is at standstill
5
Excessive speed error, 250 RPM above n-max of
rotor
6
Lid lock error
8
Lid lock error
10.1 No start code recognized
10.2 Invalid rotor code
10.3 Error during reading the rotor code
(11)* Mains interruption
13
Speed error: slippage is too high
21
Faulty speed measurement
22
Electronics U320 (A1):
23
Operating panel: Display-Timeout
25
Electronics U320 (A1):
27
Electronics U320 (A1):
29
Electronics U320 (A1):
30
Interface - error: Software protocol
31
Interface - error: Timeout
33
Interface - error: Software protocol parity bit
36
Interface - error: NAK
Page
2
I
C bus
EEPROM
EPROM
RAM
12
12
13
13
13
14
14
14
14
15
15
15
16
16
16
16
16
16
16
16
16
16

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Universal 320

Table of Contents