Blown Fuse Conditions; Sub Psu; Bcu - Ricoh J-P3 Service Manual

Table of Contents

Advertisement

20 February 2004

4.5 BLOWN FUSE CONDITIONS

Main PSU
The table lists the fuses on the main power supply unit.
Fuse
FU1
15A/125V
CB1
FU2
10A/125V
FU91
10 A/250 V

Sub PSU

The table lists the fuses on the sub power supply unit.
Fuse
F1
4A/250V
F2
8A/250V

BCU

The table lists the fuses on the sub power supply unit.
Fuse
FU1
3A/32V
FU2
FU3
Rating
115 V
220 - 240 V
8A/250V
5 A/250V
10 A/250V
Rating
115V
220–240V
3.15A/250V
8A/250V
Rating
Symptom when turning on the main switch
No response
SC 680 (BCU/ MUSIC communication error: The power
1A/24V
is not supplied to the ID chips on the toner bottles, so the
toner bottles are not recognized.)
When you turn on the main power switch, the operation
4A/24V
panel displays messages as usual but the characters are
not clear. After this, the messages and LEDs turn off.
BLOWN FUSE CONDITIONS
Symptom when turning on the main
No response (No power is supplied to
the electrical components.)
No response (No DC power is
supplied to the electrical components.)
The 24V DC power is not supplied.
The message, "Close Front Cover," is
displayed.
Symptom when turning on the main
The two-tray finisher or booklet
finisher is not detected. "Close Duplex
Unit Cover" is shown.
The two-tray finisher or booklet
finisher is not detected. "Close Duplex
Unit Cover" is shown.
4-21
switch
switch

Advertisement

Table of Contents
loading

This manual is also suitable for:

G106

Table of Contents