Ricoh J-P3 Service Manual page 125

Table of Contents

Advertisement

20 February 2004
3903
[M/A Target] M/A Target ([Color])
Adjusts the M/A (Mass per Area, mg/cm
self-check. Adjusting this changes the development bias. This causes the solid ID to
increase or decrease. If developer capability causes an ID problem, toner density
needs to be adjusted with SP3-120-1 to 4, depending on the color.
3903 001 Printer [K]
3903 002 Printer [Y]
3903 003 Printer [M]
3903 004 Printer [C]
3903 005 CF [K]
3903 006 CF [Y]
3903 007 CF [M]
3903 008 CF [C]
3904
[M/A for LD] M/A Target for LD Correction ([Color])
Adjusts the M/A value used during the LD correction mode. This value is effective
when SP3-125-2 "LD Control Selection" is set to "2".
Adjusting this data effects the image reproduction especially in highlight areas.
3904 001 Printer [K]
3904 002 Printer [Y]
3904 003 Printer [M]
3904 004 Printer [C]
3904 005 CF [K]
3904 006 CF [Y]
3904 007 CF [M]
3904 008 CF [C]
3905
[M/A Target]
3905 001 Intrvl [K]
3905 002 Intrvl [Y]
3905 003 Intrvl [M]
3905 004 Intrvl [C]
3905 005 Intrvl [K]
3905 006 Intrvl [Y]
3905 007 Intrvl [M]
3905 008 Intrvl [C]
2
) value used during the process control
*BCU
[0 to 1.50 / 0.60 / 0.01 mg/cm
*BCU
*BCU
*BCU
*
[0 to 1.50 / 0.60 / 0.01 mg/cm
*
*
*
*BCU [0 to 1.00 / 0.10 / 0.01 mg/cm2 /step] DFU
*BCU
[0 to 1.00 / 0.12 / 0.01 mg/cm2 /step] DFU
*BCU
*BCU
[0 to 1.00 / 0.13 / 0.01 mg/cm2 /step] DFU
*
*
[0 to 1.00 / 0.14 / 0.01 mg/cm2 /step] DFU
*
*
*BCU
[0 to 1.50 / 0.30 / 0.01 mg/cm
Adjusts the target amount of each toner on paper
*BCU
sheets. These values are optimized before
*BCU
shipment. Do not change the values. Changing
*BCU
these values does not affect toner density on
paper sheets.
*BCU
[0 to 1.500 / - / 0.01 mg/cm
*BCU
Displays the amount of each toner on the paper. A
*BCU
problem may have occurred in the printer engine if
*BCU
the value is high or low (i.e., if the difference
between SP3-905-1/2/3/4 and SP3-5/6/7/8 is
larger than ±0.03 mg/cm
Possible problems: Defective TD sensor, defective
ID sensor, toner near-end (if the value is lower
than the target), defective toner supply
mechanism
5-29
ENGINE SERVICE MODE
2
/step] DFU
2
/step] DFU
2
/step] DFU
2
/step]
2
).

Advertisement

Table of Contents
loading

This manual is also suitable for:

G106

Table of Contents