There are only 14 I/O parameters that could use Averaging Constant:
Digital Inputs (1-4); Analog Inputs (1-4); Battery Voltage; Battery Current;
External Voltage; PDOP; HDOP; Speedometer.
I/O parameters: "Current Profile", "Fuel level meter" (1-2), "Fuel
temperature" (1-2), "GNSS Status", "Movement", "Active GSM Operator",
"iButton ID", "Odometer", "GSM Signal", "Deep Sleep", "Cell ID", "Area
Code", "PCB Temperature", "Dallas temperature Sensor 0..2", "Fuel
Counter" and "RFID ID" cannot use Averaging constant functionality.

6.3.1.6 Configurable parameter values and Global parameter values

6.3.1.6.1 Configurable parameters

Table 25 Configurable parameter values
Parameter
ID
Sleep Mode (0 –
disable, 1 – enable,
000
2 – Deep Sleep)
Sleep Timeout
001
Ignition source
900
High Level (for
901
Ignition)
Low Level (for
902
Ignition)
Min Period (in
011
seconds)
Min Distance (in
012
meters)
Min Angle (in
013
degrees)
Min Saved Records
014
Min Send Period (in
015
seconds)
GPRS Week Time
016
CAN#8
CAN#9
CAN#10
Table 24 CAN elements and parameters
Parameter value
MIN
MAX
System parameters (chapter 6.3.1.1)
0
2
0
9000
0
1
0
30000
0
30000
Data Acquisition parameters (chapter 9)
0
9999999
0
1000000
0
360
1
25
0
9999999
-
-
Geofencing parameters (chapter 6.3.1.3.4.1)
850 – 852
860 – 862
870 – 872
Recommend
Default
0
1
0
0
0
600
0
0
10
600
-
Value type
ed
-
U8
-
U16
-
U8
-
U16
-
U16
-
U32
-
U32
-
U16
1
U8
-
U32
-
-
52