Configurable Parameter Values And Global Parameter Values; Configurable Parameters - Teltonika FM5300 User Manual

Hide thumbs Also See for FM5300:
Table of Contents

Advertisement

The rest CAN elements are configured in the same sequence. CAN elements and parameters
ID's are listed below.
There are only 14 I/O parameters that could use Averaging Constant:
Digital Inputs (1-4); Analog Inputs (1-4); Battery Voltage; Battery Current;
External Voltage; PDOP; HDOP; Speedometer.
I/O parameters: "Current Profile", "Fuel level meter" (1-2), "Fuel
temperature" (1-2), "GNSS Status", "Movement", "Active GSM Operator",
"iButton ID", "Odometer", "GSM Signal", "Deep Sleep", "Cell ID", "Area
Code", "PCB Temperature", "Dallas temperature Sensor 0..2", "Fuel
Counter" and "RFID ID" cannot use Averaging constant functionality.

6.3.1.6 Configurable parameter values and Global parameter values

Table 25 Configurable parameter values
Parameter
ID
Sleep Mode (0 –
disable, 1 – enable,
000
2 – Deep Sleep)
Min Period (in
011
seconds)
Min Distance (in
012
meters)
Min Angle (in
013
degrees)
Min Saved Records
014
Min Send Period (in
015
seconds)
GPRS Week Time
016
Table 24 CAN elements and parameters
CAN Element
CAN Element
Number
parameters
CAN#0
770 – 772
CAN#1
780 – 782
CAN#2
790 – 792
CAN#3
800 – 802
CAN#4
810 – 812
6.3.1.6.1

Configurable parameters

Parameter value
MIN
MAX
System parameters (chapter 6.3.1.1)
0
2
Data Acquisition parameters (chapter 8)
0
9999999
0
1000000
0
360
1
25
0
9999999
-
-
Recommend
Default
ed
0
-
600
-
0
-
0
-
10
1
600
-
-
-
Value type
U8
U32
U32
U16
U8
U32
-
44