7. Position the replacement front panel so the tab on the back of the front panel lines up with the slot on the Thor VM1.
Be sure the two wiring connectors are also aligned.
8. Position the replacement front panel so wiring connector on the back of the front panel lines up with the connector on
the Thor VM1.
9. Gently press the front panel into place.
10. Tighten the fourteen (14) captive M3 screws. In the order shown in the top figure above, use a #2 Phillips bit and torque
the screws to 6-7 inch pounds.
11. Reinstall the Thor VM1 in the dock.
12. When the Thor VM1 is placed in the powered dock, the UPS battery automatically reconnects.
13. Restart the Thor VM1.
14. When restarted, the Thor VM1 automatically recognizes the keyboard type (12 or 64 keys).
15. If the defroster configuration has changed, use the Test button on the
the Thor VM1 defroster configuration.
16. The Thor VM1 is ready for use.
4 - 64