After the bottom bracket has been attached to a rigid surface, you are ready to assemble the Thor VM1 bracket config-
uration.
Mounting Dimensions
Note: Drawing not to scale.
5
Step 2 - Remove RAM Ball
If the Thor VM1 dock has a RAM ball attached, the RAM ball must be removed from the dock to use the U Bracket
mount.
Remove the RAM ball. The hardware used to attach the RAM ball to the dock is not reused for the U bracket mount.
Step 3 - Attach Adapter Bracket
Note: For the steps below, always place the lock washer on the bolt before the flat washer.
1. Attach the Adapter Bracket to the Thor VM1 dock using four each M5x16mm bolt, M5 lock washer and M5 flat
washer. Torque to 35 in/lbs (4.0 N/m).
2. Attach the Thor VM1/Adapter Bracket assembly to the U Bracket using 4 each 1/4-20x5/8 bolt, 1/4 lock washer
and 1/4 flat washer.
3. If the Thor VM1 is not already mounted to the dock,
4. Adjust the Thor VM1 to the desired viewing angle.
5. Torque the 14-20 bolts to 50 in/lbs (5.6 N/m).
4 - 28
1
2
3
7
6
1. 14.40 in / 359.2 mm
2. 12.10 in / 307.3 mm
3. 6.05 in / 153.6 mm
4
4. 1.02 in / 25.9 mm
5. 3.38 in / 85.85 mm
6. Vehicle Mount Footprint
9
8
7. 0.406 in / 10.312 mm
8. 0.88 in / 22.3 mm
9. 1.25 in / 31.75 mm
Place Thor VM1 in the Dock
(page 4-18).