Installing The Sas/Pcie* Sff Combo Power Docking Board; Replacing The Fan; Removing The Fan; Figure 68. Removing The Sas/Pcie* Sff Combo Power Docking Board - Intel S2600TP series Service Manual

Table of Contents

Advertisement

Intel® Server Board S2600TP and Intel® Compute Module HNS2600TP Product Family
Figure 68.
2.16.2

Installing the SAS/PCIe* SFF Combo Power Docking Board

1.
Place the power docking board into the compute module base (see letter A).
2.
Check the rubber bumper is in the mounting hole (see letter B).
3.
Secure the power docking board with the five screws (see letter C).
4.
Connect all cables to the power docking board.
5.
Install the bridge board. For instructions, see
Figure 69.

2.17 Replacing the Fan

2.17.1

Removing the Fan

1.
Disconnect the fan cable from the power docking board.
2.
Grasp the fan from the top and pull it out of the fan bracket.
34
Removing the SAS/PCIe* SFF Combo Power Docking Board
Installing the SAS/PCIe* SFF Combo Bridge
Installing the SAS/PCIe* SFF Combo Power Docking Board
Board.