For iSCSI interfaces
1. In the Navigator 2 GUI, access the array and click iSCSI Targets in the
Groups tree view. The iSCSI Targets screen displays.
2. Click the check box for the iSCSI Targets that you want to connect to the
HP server.
3. Click Edit Target. The Edit iSCSI Target screen appears.
4. Select the Options tab.
5. From the Platform drop-down list, select HP-UX. Doing this causes
"Enable HP-UX Mode" and "Enable PSUE Read Reject Mode" to be
selected in the Additional Setting box.
6. Click OK. A message appears, click Close.

Windows Server 2000

A P-VOL and S-VOL cannot be made into a dynamic disk on Windows
Server 2000 and Windows Server™ 2008.
Native OS mount/dismount commands can be used for all platforms,
except Windows Server 2000. The native commands on this
environment do not guarantee that all data buffers are completely
flushed to the volume when dismounting. In these instances, you must
use CCI to perform volume mount/unmount operations. For more
information on the CCI mount/unmount commands, see the Hitachi
AMS Command Control Interface (CCI) Reference Guide.

Windows Server 2003/2008

A P-VOL and S-VOL can be made into a dynamic disk on Windows
Server 2003.
In Windows Server™ 2008, refer to the Hitachi Adaptable Modular
Storage Command Control Interface (CCI) Reference Guide for the
restrictions when the mount/unmount command is used.
Windows
resynchronized while retaining data on the S-VOL on the server
memory, the compatible backup cannot be collected. Therefore,
execute the CCI sync command immediately before re-synchronizing
the pair for the un-mounted S-VOL.
In Windows Server™ 2008, set only the P-VOL of TCE to be recognized
by the host and let another host recognize the S-VOL.
(CCI only) If a path detachment is caused by controller detachment or
Fibre Channel failure, and the detachment continues for longer than
one minute, the command device may not be recognized when
recovery occurs. In this case, execute the "re-scanning of the disks" in
Windows. If Windows cannot access the command device, though CCI
recognizes the command device, restart CCI.
Volumes to be recognized by the same host: If you recognize the P-VOL
and S-VOL on Windows Server 2008 at the same time, it may cause an
error because the P-VOL and S-VOL have the same disk signature.
When the P-VOL and S-VOL have the same data, split the pair and then
Plan and design—arrays, volumes and operating systems
Hitachi AMS 2000 Family TrueCopy Extended Distance User Guide
®
may write for the un-mounted volume. If a pair is
4–7