12.Enter the following in the command prompt to verify the connection
between CCI and the array:
C:\>cd horcm\etc
C:\horm\etc>echo hd1-3 | .\inqraid
Harddisk 1 -> [ST] CL1-A Ser =85000174 LDEV =
CM
]
Harddisk 2 -> [ST] CL1-A Ser =85000174 LDEV = 1 [HITACHI ] [DF600F
]
Harddisk 3 -> [ST] CL1-A Ser =85000175 LDEV = 2 [HITACHI ] [DF600F
]
C:\horm\etc>

Setting the environment variable

The environment variable must be set up for the execution environment.
The following describes an example in which two instances (0 and 1) are
configured on the same Windows 2000/Windows server.
1. Set the environment variable for each instance. Enter the following from
the command prompt:
C:\HORCM\etc>set HORCMINST=0
2. Execute the horcmstart script, and then execute the pairdisplay
command to verify the configuration. For example:
C:\HORCM\etc>horcmstart 0 1
starting HORCM inst 0
HORCM inst 0 starts successfully.
starting HORCM inst 1
HORCM inst 1 starts successfully.
C:\HORCM\etc>pairdisplay -g VG01
group
PairVOL(L/R) (Port#,TID, LU) ,Seq#,LDEV#.P/S,Status,Fence, Seq#,P-
LDEV# M
VG01
oradb1(L)
-
----
-
VG01
oradb1(R)
-
----
-
B–6
Hitachi AMS 2000 Family TrueCopy Extended Distance User Guide
HORC = SMPL
HOMRCF[MU#0 = NONE
RAID5[Group
1-0] SSID = 0x0000
HORC = SMPL
HOMRCF[MU#0 = NONE
RAID5[Group
2-0] SSID = 0x0000
(CL1-A , 1,
(CL1-A , 1,
Operations using CCI
0 [HITACHI
MU#1 = NONE
MU#1 = NONE
1 )85000174
1.SMPL ---- ------,----
2 )85000175
2.SMPL ---- ------,----
] [DF600F-
MU#2 = NONE]
MU#2 = NONE]