Emerson Unidrive M400 Series User Manual page 92

Variable speed ac drive for induction motors
Hide thumbs Also See for Unidrive M400 Series:
Table of Contents

Advertisement

Safety
Product
Mechanical
information
information
installation
Figure 11-5 Menu 3 Logic Diagram
Digital 6/7
Input Select
08.036
Digital input 6
0
15
1
2
Digital input 7
0
16
1
2
T10 DO1 Control
T10 DI/O 01 Source/
Destination B
08.121
08.021
T10 Digital IO1
Source/Destination A
At Zero
??.???
Frequency
10.003
??.???
Any valid
parameter
92
Electrical
Getting
Basic
installation
started
parameters
Rotary Lines
Per Revolution
03.134
03.142
03.127
Encoder
Frequency
Filter
Feedback
Position
Scaling
32 Bit
03.035
Position
03.036
Counter
Maximum
2
Reference
Frequency
1
03.043
0
08.091
≥1
03.037
Frequency Output or
Maximum Output
PWM Output Scaling
Frequency
Running
NV Media Card
Optimization
the motor
Revolution
Counter
03.128
03.143
Maximum
Frequency
Feedback
Position
03.032
Counter Reset
Position
03.029
Frequency
Two Point Minimum
03.047
Reference
Frequency
Drive Reference at
03.048
Minimum Frequency
Two Point Maximum
03.049
Frequency
Drive Reference at
03.050
Maximum Frequency
T10 Digital I/O
01 Output Select
08.031
0 to 1
2 or 3
03.038
The parameters are all shown in their default settings
Onboard
Advanced
Operation
PLC
parameters
08.086
≥1
03.045
03.044
Frequency
Reference
Scaling
T10 Digital
I/O 1
10
Key
Input
Read-write (RW)
mm.ppp
terminals
parameter
Read-only (RO)
Output
mm.ppp
parameter
terminals
Unidrive M400 Control User Guide
UL
Diagnostics
information
T15 DI6 Control
T15 DI 06
08.126
Destination B
T15 Digital input
08.026
6 Destination A
Any unprotected
bit parameter
??.???
06.031
Jog
??.???
Forward
Issue Number: 1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents