Changing the operating mode

Procedure
Use the following procedure only if a different operating mode is
required:
1. Ensure the drive is not enabled, i.e. drive is in Inhibit or Under
Voltage State.
2. Change the setting of Pr 00.079 as follows:
Pr 00.079 setting
The figures in the second column apply when serial communications are
used.
NOTE
When the operating mode is changed, a parameter save is carried out.
3. Either:
Press the red
reset button
Carry out a drive reset through serial communications by setting
Pr 10.038 to 100.
5.6

Saving parameters

When changing a parameter in Menu 0, the new value is saved when
pressing the Enter button
parameter edit mode.
If parameters have been changed in the advanced menus, then the
change will not be saved automatically. A save function must be carried
out.
Procedure
1. Select 'Save parameters' in Pr mm.000 (alternatively enter a value
of 1001 in Pr mm.000)
2. Either:
Press the red
reset button
Carry out a drive reset through serial communications by setting
Pr 10.038 to 100
5.7

Restoring parameter defaults

Restoring parameter defaults by this method saves the default values in
the drives memory. User security status (00.010) and User security code
(00.025) are not affected by this procedure).
Procedure
1. Ensure the drive is not enabled, i.e. drive is in Inhibit or Under
Voltage State.
2. Select 'Reset 50 Hz Defs' or 'Reset 60 Hz Defs' in Pr mm.000.
(alternatively, enter 1233 (50 Hz settings) or 1244 (60 Hz settings) in
Pr mm.000).
3. Either:
Press the red
reset button
Carry out a drive reset through serial communications by setting
Pr 10.038 to 100
Unidrive M400 Control User Guide
Issue Number: 1
Electrical
Getting
Basic
installation
started
parameters
Operating mode
1
Open-loop
2
RFC-A
to return to parameter view mode from
Running
NV Media Card
Optimization
the motor
Operation
5.8

Parameter access level and security

The parameter access level determines whether the user has access to
Menu 0 only or to all the advanced menus (Menus 1 to 30) in addition to
Menu 0.
The User Security determines whether the access to the user is read
only or read write.
Both the User Security and Parameter Access Level can operate
independently of each other as shown in Table 5-7.
Table 5-7 Parameter access level and security
User
security
Access
status
level
(00.010)
0
Menu 0
1
All Menus
Read-only
2
Menu 0
3
Read-only
4
Status only
5
No access
The default settings of the drive are Parameter Access Level Menu 0
and user Security Open i.e. read / write access to Menu 0 with the
advanced menus not visible.
5.8.1
User Security Level / Access Level
The drive provides a number of different levels of security that can be set
by the user via User Security Status (00.010); these are shown in the
table below.
User Security
Status
(Pr 00.010)
All writable parameters are available to be edited
Menu 0 (0)
but only parameters in Menu 0 are visible
All parameters are visible and all writable
All menus (1)
parameters are available to be edited
Read- only
Access is limited to Menu 0 parameters only. All
Menu 0 (2)
parameters are read-only
All parameters are read-only however all menus
Read-only (3)
and parameters are visible
The keypad remains in status mode and no
Status only (4)
parameters can be viewed or edited
The keypad remains in status mode and no
parameters can be viewed or edited. Drive
No access (5)
parameters cannot be accessed via a comms
interface
5.8.2
Changing the User Security Level /Access
Level
The security level is determined by the setting of Pr 00.010 or Pr 11.044.
The Security Level can be changed through the keypad even if the User
Security Code has been set.
Onboard
Advanced
Diagnostics
PLC
parameters
User
Advanced
Menu 0
security
status
(00.025)
None
RW
Not visible
None
RW
RW
Open
RW
Not visible
Closed
RO
Not visible
Open
RW
RW
Closed
RO
RO
Open
RW
RW
Closed
Not visible
Not visible
Open
RW
RW
Closed
Not visible
Not visible
Description
UL
information
menu
status
33