Emerson Unidrive M400 Series User Manual page 105

Variable speed ac drive for induction motors
Hide thumbs Also See for Unidrive M400 Series:
Table of Contents

Advertisement

Safety
Product
Mechanical
information
information
installation
Parameter
07.001
Analog Input 1 (T2/3)
07.002
Analog Input 2 (T5)
07.004
Stack Temperature
07.005
Auxiliary Temperature
07.007
Analog Input 1 Mode (T2/3)
07.008
Analog Input 1 Scaling (T2/3)
07.009
Analog Input 1 Invert (T2/3)
07.010
Analog Input 1 Destination A (T2/3)
07.011
Analog Input 2 Mode (T5)
07.012
Analog Input 2 Scaling (T5)
07.013
Analog Input 2 Invert (T5)
07.014
Analog Input 2 Destination A (T5)
07.019
Analog Output 1 Source A (T7)
07.020
Analog Output 1 Scaling (T7)
07.021
Analog Output 1 Mode (T7)
07.022
Analog Output 2 Source A (T8)
07.023
Analog Output 2 Scaling (T8)
07.024
Analog Output 2 Mode (T8)
07.026
Analog Input 1 Preset on Current Loss (T2/3)
07.027
Analog Input 2 Preset on Current Loss (T5)
07.028
Analog Input 1 Current Loop Loss (T2/3)
07.029
Analog Input 2 Current Loop Loss (T5)
07.030
Analog Input 1 Offset (T2/3)
07.031
Analog Input 2 Offset (T5)
07.034
Inverter Temperature
07.035
Percentage Of d.c. Link Thermal Trip Level
07.036
Percentage Of Drive Thermal Trip Level
07.037
Temperature Nearest To Trip Level
07.046
Thermistor Type
07.047
Thermistor Feedback
07.048
Thermistor Trip Threshold
07.049
Thermistor Reset Threshold
07.050
Thermistor Temperature
07.051
Analog Input 1 Control (T2/3)
07.052
Analog Input 2 Control (T5)
07.055
Analog Output 1 Control (T7)
07.056
Analog Output 2 Control (T8)
07.061
Analog Input 1 Minimum Reference (T2/3)
07.062
Analog Input 1 At Minimum Reference (T2/3)
07.063
Analog Input 1 Maximum Reference (T2/3)
07.064
Analog Input 1 At Maximum Reference (T2/3)
07.065
Analog Input 2 Minimum Reference (T5)
07.066
Analog Input 2 At Minimum Reference (T5)
07.067
Analog Input 2 Maximum Reference (T5)
07.068
Analog Input 2 At Maximum Reference (T5)
07.090
Analog Input 1 Destination B (T2/3)
07.094
Analog Input 2 Destination B (T5)
07.099
Analog Output 1 Source B (T7)
07.102
Analog Output 2 Source B (T8)
RW Read / Write
RO
Read only
ND
No default value
NC
Not copied
Unidrive M400 Control User Guide
Issue Number: 1
Electrical
Getting
Basic
installation
started
parameters
the motor
Range ( )
OL
±100.00 %
0.00 to 100.00 %
±250 °C
±250 °C
4-20mA Stop (-6), 20-4mA Stop (-5),
4-20mA Low (-4), 20-4mA Low (-3),
4-20mA Hold (-2), 20-4mA Hold (-1), 0-20mA (0),
20-0mA (1), 4-20mA Trp (2), 20-4mA Trp (3),
4-20mA (4), 20-4mA (5), Voltage (6)
0.000 to 10.000
Off (0) or On (1)
0.000 to 30.999
4-20mA Stop (-6), 20-4mA Stop (-5),
4-20mA Low (-4), 20-4mA Low (-3),
4-20mA Hold (-2), 20-4mA Hold (-1), 0-20mA (0),
20-0mA (1), 4-20mA Trp (2), 20-4mA Trp (3),
4-20mA (4), 20-4mA (5), Voltage (6), Digital (7)
0.000 to 10.000
Off (0) or On (1)
0.000 to 30.999
0.000 to 30.999
0.000 to 40.000
Voltage (0), 0-20mA (1), 4-20mA (2), Digital (3)
0.000 to 30.999
0.000 to 40.000
Voltage (0), 0-20mA (1), 4-20mA (2), Digital (3)
4.00 to 20.00
4.00 to 20.00
Off (0) or On (1)
Off (0) or On (1)
±100.00 %
±100.00 %
±250 °C
0 to 100 %
0 to 100 %
0 to 29999
DIN44081 (0), KTY84 (1), PT1000 (2), PT2000 (3),
Other (4)
0 to 4000 Ω
0 to 4000 Ω
0 to 4000 Ω
-50 to 300 °C
0 to 5
0 to 5
0 to 15
0 to 15
±100.00 %
±100.00 %
±100.00 %
±100.00 %
0.00 to 100.00 %
±100.00 %
0.00 to 100.00 %
±100.00 %
0.000 to 30.999
0.000 to 30.999
0.000 to 30.999
0.000 to 30.999
Num Number parameter
Bit
PT
Protected parameter
RA
Running
NV Media Card
Optimization
Operation
RFC-A
OL
Bit parameter
Txt
Text string
Rating dependent
US
User save
Onboard
Advanced
Diagnostics
PLC
parameters
Default ( )
RFC-A
RO
Num
RO
Num
RO
Num
RO
Num
Voltage (6)
RW
Txt
1.000
RW
Num
Off (0)
RW
Bit
1.036
RW
Num
Voltage (6)
RW
Txt
1.000
RW
Num
Off (0)
RW
Bit
1.037
RW
Num
2.001
RW
Num
1.000
RW
Num
Voltage (0)
RW
Txt
4.002
RW
Num
1.000
RW
Num
Voltage (0)
RW
Txt
4.00
RW
Num
4.00
RW
Num
RO
Bit
RO
Bit
0.00 %
RW
Num
0.00 %
RW
Num
RO
Num
RO
Num
RO
Num
RO
Num
DIN44081 (0)
RW
Txt
RO
Num
3300 Ω
RW
Num
1800 Ω
RW
Num
RO
Num
0
RW
Num
0
RW
Num
0
RW
Num
0
RW
Num
-100.00 %
RW
Num
-100.00 %
RW
Num
100.00 %
RW
Num
100.00 %
RW
Num
0.00 %
RW
Num
0.00 %
RW
Num
100.00 %
RW
Num
100.00 %
RW
Num
RO
Num
RO
Num
RO
Num
RO
Num
Bin
Binary parameter
PS
Power-down save
UL
information
Type
ND
NC
PT
FI
ND
NC
PT
FI
ND
NC
PT
ND
NC
PT
US
US
US
DE
PT
US
US
US
US
DE
PT
US
PT
US
US
US
PT
US
US
US
US
US
ND
NC
PT
ND
NC
PT
US
US
ND
NC
PT
ND
NC
PT
ND
NC
PT
ND
NC
PT
US
ND
NC
PT
FI
US
US
ND
NC
PT
FI
US
US
US
US
US
US
US
US
US
US
US
US
DE
PT
US
DE
PT
US
PT
US
PT
US
FI
Filtered
DE
Destination
105

Hide quick links:

Advertisement

Table of Contents
loading