Emerson Unidrive M400 Series User Manual page 100

Variable speed ac drive for induction motors
Hide thumbs Also See for Unidrive M400 Series:
Table of Contents

Advertisement

Safety
Product
Mechanical
information
information
installation
Parameter
05.001
Output Frequency
05.002
Output Voltage
05.003
Output Power
05.004
Motor Rpm
05.005
D.C. Bus Voltage
05.006
Motor Rated Frequency
05.007
Motor Rated Current
05.008
Motor Rated Speed
05.009
Motor Rated Voltage
05.010
Motor Rated Power Factor
05.011
Number Of Motor Poles*
05.012
Auto-tune
Dynamic V To F Select
05.013
Flux Optimization Select
05.014
Control Mode
05.015
Low Frequency Voltage Boost
05.017
Stator Resistance
05.018
Maximum Switching Frequency
05.019
High Stability Space Vector Modulation
05.020
Over Modulation Enable
05.021
Mechanical Load Test Level
05.024
Transient Inductance
05.025
Stator Inductance
05.026
High Dynamic Performance Enable
05.027
Enable Slip Compensation
05.028
Flux Control Compensation Disable
05.029
Saturation Breakpoint 1
05.030
Saturation Breakpoint 3
05.031
Voltage Controller Gain
05.032
Torque Per Amp
05.033
Slip Compensation Limit
05.034
Percentage Flux
05.035
Auto-switching Frequency Change Disable
05.036
Slip Compensation Filter
05.037
Switching Frequency
05.038
Minimum Switching Frequency
05.040
Spin Start Boost
05.042
Reverse Output Phase Sequence
05.059
Maximum Deadtime Compensation
05.060
Current At Maximum Deadtime Compensation
05.061
Disable Deadtime Compensation
05.062
Saturation Breakpoint 2
05.063
Saturation Breakpoint 4
05.074
Boost End Voltage
05.075
Boost End Frequency
05.076
Second Point Voltage
05.077
Second Point Frequency
05.078
Third point voltage
05.079
Third point frequency
05.080
Low acoustic noise enable
Change to maximum drive switching
05.081
frequency at low output current
05.083
Voltage Shelving Disable
Low Frequency Slip Boost
05.084
Low Frequency Estimator Threshold
05.088
Ur Mode Pre-Flux Delay
* If this parameter is read via serial communications, it will show pole pairs.
RW Read / Write
RO
Read only
ND
No default value
NC
Not copied
100
Electrical
Getting
Basic
installation
started
parameters
the motor
Range ( )
OL
VM_SPEED_FREQ_REF Hz
0 to VM_AC_VOLTAGE V
VM_POWER kW
±33000.0 rpm
0 to VM_DC_VOLTAGE V
0.00 to 550.00 Hz
0.00 to VM_RATED_CURRENT A
0.0 to 33000.0 rpm
0 to VM_AC_VOLTAGE_SET V
0.00 to 1.00
Automatic (0) to 32 (16) Poles
0 to 2
0 to 1
Ur S (0), Ur (1),
Fixed (2), Ur Auto (3),
Ur I (4), Square (5),
Fixed Tapered (6)
0.0 to 25.0 %
0.0000 to 99.9999 Ω
0.667 (0), 1 (1), 2 (2),
3 (3), 4 (4), 6 (5), 8 (6),
12 (7), 16 (8) kHz
Off (0) or On (1)
Off (0) or On (1)
0.000 to 500.000 mH
0.00 to 5000.00 mH
±150.0 %
Off (0) or On (1)
1 to 30
0.00 to 500.00 Nm/A
0.00 to 10.00 Hz
0 to 2
64 (0), 128 (1), 256 (2),
512 (3) ms
0.667 (0), 1 (1), 2 (2),
3 (3), 4 (4), 6 (5), 8 (6),
12 (7), 16 (8) kHz
0 to VM_MAX_SWITCHING_
FREQUENCY kHz
0.0 to 10.0
Off (0) or On (1)
0.000 to 10.000 µs
0.00 to 100.00 %
Off (0) or On (1)
0.0 to 100.0 %
0.0 to 100.0 %
0.0 to 100.0 %
0.0 to 100.0 %
0.0 to 100.0 %
0.0 to 100.0 %
Off (0) or On (1)
Off (0) or On (1)
Off (0) or On (1)
0.0 to 100.0 %
0.0 to 0.7 s
Num Number parameter
Bit
PT
Protected parameter
RA
Running
NV Media Card
Optimization
Operation
Default ( )
RFC-A
OL
50Hz: 50.00 Hz, 60Hz: 60.00 Hz
Maximum Heavy Duty Rating (11.032)
50 Hz: 1500.0 rpm
60 Hz: 1800.0 rpm
110 V drive: 230 V, 200 V drive: 230 V
400 V drive 50 Hz: 400 V,
400 V drive 60 Hz: 460 V
575 V drive: 575 V, 690 V drive: 690 V
0.85
Automatic (0) Poles
0 to 3
0
0 to 1
Ur I (4)
3.0 %
0.0000 Ω
2 (2), 3 (3), 4 (4),
6 (5), 8 (6), 12 (7),
3 (3) kHz
16 (8) kHz
Off (0)
Off (0)
0 to 100 %
0.000 mH
0.00 mH
Off (0) or On (1)
100.0 %
Off (0)
0.0 to 100.0 %
0.0 to 100.0 %
10.00 Hz
0.0 to 150.0 %
128 (1) ms
2 (2), 3 (3), 4 (4),
6 (5), 8 (6), 12 (7),
16 (8) kHz
0.667 (0) kHz
Off (0)
Off (0)
0.0 to 100.0 %
0.0 to 100.0 %
50.0 %
50.0 %
55.0 %
55.0 %
75.0 %
75.0 %
Off (0)
Off (0)
Off (0)
0.0 %
0.0 to 100.0 %
0.5 s
Bit parameter
Txt
Text string
Rating dependent
US
User save
Onboard
Advanced
Diagnostics
PLC
parameters
RFC-A
RO
Num
ND
RO
Num
ND
RO
Num
ND
RO
Num
ND
RO
Num
ND
RW
Num
RW
Num
50 Hz: 1450.0 rpm
RW
Num
60 Hz: 1750.0 rpm
RW
Num
RW
Num
RW
Txt
0
RW
Num
RW
Num
0 to 1
RW
Num
RW
Txt
RW
Num
RW
Num
RW
Txt
RW
Bit
RW
Bit
0 %
RW
Bit
RW
Num
RW
Num
Off (0)
RW
Bit
RW
Num
RW
Bit
50.0 %
RW
Num
75.0 %
RW
Num
1
RW
Num
RO
Num
ND
RW
Num
RO
Num
ND
0
RW
Num
RW
Txt
RO
Txt
ND
RW
Txt
1.0
RW
Num
RW
Bit
RO
Num
RO
Num
RW
Bit
0.0 %
RW
Num
0.0 %
RW
Num
RW
Num
RW
Num
RW
Num
RW
Num
RW
Num
RW
Num
RW
Bit
RW
Bit
RW
Bit
RW
Num
RW
Num
0.0 %
RW
Num
Bin
Binary parameter
PS
Power-down save
Unidrive M400 Control User Guide
Issue Number: 1
UL
information
Type
NC
PT
FI
NC
PT
FI
NC
PT
FI
NC
PT
FI
NC
PT
FI
US
RA
US
US
RA
US
RA
US
US
NC
US
US
US
US
RA
US
RA
US
US
US
US
RA
US
RA
US
US
US
US
US
US
US
NC
PT
US
NC
PT
US
US
NC
PT
RA
US
US
NC
PT
US
NC
PT
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
US
FI
Filtered
DE
Destination

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents