Advanced Menus - Emerson Unidrive M400 Series User Manual

Variable speed ac drive for induction motors
Hide thumbs Also See for Unidrive M400 Series:
Table of Contents

Advertisement

Safety
Product
Mechanical
information
information
installation
Table 5-3 CI-Keypad set-up parameters
Parameters
Keypad.00 Language
Keypad.01 Show Units
Keypad.02 Backlight Level
Keypad.05 Show Raw Text Parameter Values Off or On
Keypad.06 Software Version
Keypad.07 Language version
Keypad.08 Font version
NOTE
The languages available will depend on the keypad software version.
* Keypad.08 will depend on the keypad software version.
NOTE
It is not possible to access the keypad parameters via any
communications channel.
5.4

Advanced menus

The advanced menus consist of groups or parameters appropriate to a
specific function or feature of the drive. Menus 0 to 30 can be viewed on
the Keypad.
The option module menu (1.mm.ppp) is only displayed if the option
module is installed. Where 1 signifies the option module slot number and
the mm.ppp signifies the menu and parameter number of the option
module's internal menus and parameters.
Table 5-4 Advanced menu descriptions
Menu
Commonly used basic set up parameters for quick / easy
0
programming
1
Frequency reference
2
Ramps
3
Frequency control
4
Torque and current control
5
Motor control
6
Sequencer and clock
7
Analog I/O
8
Digital I/O
Programmable logic, motorized pot, binary sum, timers and
9
scope
10
Status and trips
11
Drive set-up and identification, serial communications
12
Threshold detectors and variable selectors
14
User PID controller
15
Option module slot 1 set-up menu
18
General option module application menu 1
20
General option module application menu 2
21
Second motor parameters
22
Menu 0 set-up
24
Option module slot 1 application menu
30
Onboard user programming application menu
Slot 1
Slot 1 option menus*
* Only displayed when the option module is installed.
32
Electrical
Getting
Basic
installation
started
parameters
Range
English, French,
German, Italian,
Spanish and
Chinese
Off or On
0 to 100 %
00.00.00.00 to
99.99.99.99
00.00.00.00 to
99.99.99.99
0 to 99
Description
Running
NV Media Card
Optimization
the motor
Operation
5.4.1
Display messages
The following tables indicate the various possible mnemonics which can
Type
be displayed by the drive and their meaning.
Table 5-5 Status indications
RW
Upper row
RW
string
RW
RW
The drive is inhibited and cannot be run.
The Safe Torque Off signals are not
RO
applied to the Safe Torque Off terminals or
Inhibit
Pr 06.015 is set to 0. The other conditions
RO
that can prevent the drive from enabling
are shown as bits in Enable Conditions
RO
(06.010).
The drive is ready to run. The drive enable
Ready
is active, but the drive inverter is not active
because the final drive run is not active.
The drive is stopped / holding zero
Stop
frequency.
Run
The drive is active and running.
Supply Loss
Supply loss condition has been detected
The motor is being decelerated to zero
Deceleration
frequency because the final drive run has
been deactivated.
dc Injection
The drive is applying dc injection braking.
The drive has tripped and no longer
Trip
controlling the motor. The trip code
appears in the lower display.
Under
The drive is in the under voltage state
Voltage
either in low voltage or high voltage mode.
Heat
The motor pre-heat function is active
5.4.2
Alarm indications
An alarm is an indication given on the display by alternating the alarm
string with the drive status string on the display. Alarms strings are not
displayed when a parameter is being edited.
Table 5-6 Alarm indications
Alarm string
Brake resistor overload. Braking Resistor Thermal
Brake Resistor
Accumulator (10.039) in the drive has reached
75.0 % of the value at which the drive will trip.
Motor Protection Accumulator (04.019) in the drive
Motor Overload
has reached 75.0 % of the value at which the drive
will trip and the load on the drive is >100 %.
Drive over temperature. Percentage Of Drive
Drive overload
Thermal Trip Level (07.036) in the drive is greater
than 90 %.
The autotune procedure has been initialized and an
Auto Tune
autotune in progress.
Limit switch active. Indicates that a limit switch is
Limit Switch
active and that is causing the motor to be stopped.
Option Slot 1
Option slot alarm.
Low AC
Low voltage mode. See Low AC Alarm (10.107).
Current limit active. See Current Limit Active
Current Limit
(10.009).
24V Backup
24V Backup not present. See 24V Alarm Loss
Lost
Enable (11.098)
Onboard
Advanced
Diagnostics
PLC
parameters
Description
Description
Unidrive M400 Control User Guide
Issue Number: 1
UL
information
Drive
output
stage
Disabled
Disabled
Enabled
Enabled
Enabled
Enabled
Enabled
Disabled
Disabled
Enabled

Hide quick links: