VM_SPEED_FREQ_USER_REFS
Units
Hz
Range of [MIN]
-550.00 to 550.00
Range of [MAX]
0.00 to 550.00
This variable maximum is applied to Analog Reference 1 (01.036), Analog Reference 2 (01.037) and Keypad
Reference (01.017).
The maximum applied to these parameters is the same as other frequency reference parameters.
VM_SPEED_FREQ_USER_REFS [MAX] = VM_SPEED_FREQ_REF[MAX]
However the minimum is dependent on Negative Reference Clamp Enable (01.008) and Bipolar Reference Enable
(01.010).
Definition
VM_SUPPLY_LOSS_LEVEL
Units
V
Range of [MIN]
0 to 1150
Range of [MAX]
0 to 1150
VM_SUPPLY_LOSS_LEVEL[MAX] = VM_DC_VOLTAGE_SET[MAX]
Definition
VM_SUPPLY_LOSS_LEVEL[MIN] is drive voltage rating dependent. See Table 11-4
VM_TORQUE_CURRENT
Units
%
Range of [MIN]
-1000.0 to 0.0
Range of [MAX]
0.0 to 1000.0
VM_TORQUE_CURRENT[MIN] = -VM_TORQUE_CURRENT[MAX]
Definition
VM_TORQUE_CURRENT_UNIPOLAR
Units
%
Range of [MIN]
0.0
Range of [MAX]
0.0 to 1000.0
VM_TORQUE_CURRENT_UNIPOLAR[MAX] = VM_TORQUE_CURRENT[MAX]
VM_TORQUE_CURRENT_UNIPOLAR[MIN] =0.0
User Current Maximum Scaling (04.024) defines the variable maximum/minimums VM_USER_CURRENT which is
applied to Percentage Load (04.020) and Torque Reference (04.008). This is useful when routing these parameters to
Definition
an analog output as it allows the full scale output value to be defined by the user. This maximum is subject to a limit of
MOTOR1_CURRENT_LIMIT or MOTOR2_CURRENT_LIMIT depending on which motor map is currently active.
The maximum value (VM_TORQUE_CURRENT_UNIPOLAR [MAX]) varies between drive sizes with default
parameters loaded. For some drive sizes the default value may be reduced below the value given by the parameter
range limiting.
80
Electrical
Getting
Basic
installation
started
parameters
Range applied to analog reference parameters
Negative Reference Clamp Enable
(01.008)
0
0
1
1
Range applied to the supply loss threshold
Range applied to torque and torque producing current parameters
Select Motor 2 Parameters (11.045)
0
1
Unipolar version of VM_TORQUE_CURRENT
Running
NV Media Card
Optimization
the motor
Operation
Bipolar Reference Enable
(01.010)
0
1
0
1
VM_MOTOR1_CURRENT_LIMIT[MAX]
VM_MOTOR2_CURRENT_LIMIT[MAX]
Onboard
Advanced
Diagnostics
PLC
parameters
VM_SPEED_FREQ_USER_REFS[MIN]
If Select Motor 2 Parameters (11.045) = 0
Minimum Reference Clamp (01.007),
otherwise M2 Minimum Reference Clamp
(21.002)
-VM_SPEED_FREQ_REF[MAX]
0.00
-VM_SPEED_FREQ_REF[MAX]
VM_TORQUE_CURRENT[MAX]
Unidrive M400 Control User Guide