7.8.3

Transition zones

Transition zones are areas close to the process connector and close to the end of probe where
measurements have reduced accuracy, see table below.
For more information on transitions zones for the various sensor configuration (i.e. coax, rope, rod,
HTHP, etc.), refer to SLG 700 SmartLine Level Transmitter User's manual,
Table 21: Minimum blocking distances and transition zones for the various probe
Probe
Media in
Type
Water
Rod/Wire
(DC=80)
Rod/Wire
Oil (DC=2)
Water
Coax
(DC=80)
Coax
Oil (DC=2)
Revision 5
Minimum
Blocking
Tank
Distance
High [cm]
9
7
5
5
SLG 700 Series HART Option User's Manual
types
Upper
Minimum
Transition
Blocking
Zone, T
Distance
up
[cm]
Low [cm]
13
14
14
8
#34-SL-25-11.
Lower
Transition
Zone, T
low
[cm]
0
1
0
12
2
0
6
7