Table 23A — 19XRV Heat Exchanger Data — Drive End Entering Cooler Water (cont)
DRY RIGGING
WEIGHT
(LB)*
CODE†
COOLER
CONDENSER
ONLY
ONLY
6K
5716
6L
5804
6M
5894
6P
5768
6Q
5852
6R
5938
6T
6230
6U
6330
6V
6433
6X
6293
6Y
6388
6Z
6487
70
9942
10786
71
10330
11211
72
10632
11622
73
10715
11737
74
10790
11775
75
10840
11859
76
11289
12345
77
11638
12814
78
11738
12949
79
11828
12994
7K
8728
7L
8959
7M
9161
7P
8792
7Q
9023
7R
9229
7T
9431
7U
9698
7V
9932
7X
9510
7Y
9777
7Z
10016
80
12664
12753
81
12998
13149
82
13347
13545
83
13437
13872
84
13523
14217
85
13804
14008
86
14191
14465
87
14597
14923
88
14705
15311
89
14808
15721
8K
11153
8L
11400
8M
11650
8P
11219
8Q
11470
8R
11719
8T
12069
8U
12357
8V
12645
8X
12152
8Y
12444
8Z
12733
*Rigging weights are for standard tubes of standard wall thickness
(0.025-in. [0.635 mm] wall).
†Heat exchanger frame sizes 2 through 6 available on single-stage
chillers only.
NOTES:
1. Cooler includes the control panel (ICVC), suction elbow, and
distribution piping weight.
ENGLISH
MACHINE CHARGE
REFRIGERANT
WATER WEIGHT
WEIGHT (LB)
COOLER CONDENSER COOLER CONDENSER
760
1291
797
1341
828
1399
725
1338
764
1385
798
1439
863
1405
905
1462
941
1528
823
1459
868
1512
906
1574
1409
840
2008
1539
840
2164
1646
840
2286
1622
840
2328
1584
840
2366
1599
950
2183
1747
950
2361
1869
950
2501
1849
950
2548
1806
950
2592
1047
1948
1132
2094
1214
2229
1002
2010
1087
2156
1167
2295
1194
2115
1292
2282
1403
2436
1142
2185
1240
2352
1347
2511
1700
836
2726
1812
836
2863
1928
836
3005
1877
836
3053
1840
836
3099
1927
945
2951
2054
945
3108
2186
945
3271
2142
945
3325
2099
945
3378
1385
2760
1484
2926
1589
3088
1334
2830
1430
2999
1535
3161
1580
2991
1694
3180
1814
3365
1522
3070
1632
3264
1752
3448
DRY RIGGING
WEIGHT
(KG)*
COOLER
CONDENSER
(LB)
ONLY
ONLY
2595
2635
2676
2619
2657
2696
2828
2874
2921
2857
2900
2945
2225
4514
4897
2389
4690
5090
2548
4827
5276
2604
4865
5329
2622
4899
5346
2431
4921
5384
2619
5125
5605
2801
5284
5818
2864
5329
5879
2885
5370
5899
3963
4067
4159
3992
4096
4190
4282
4403
4509
4318
4439
4547
2977
5749
5790
3143
5901
5970
3309
6060
6149
3476
6100
6298
3651
6139
6455
3238
6267
6360
3428
6443
6567
3618
6627
6775
3608
6676
6951
4009
6723
7137
5063
5176
5289
5093
5207
5320
5479
5610
5741
5517
5650
5781
2. Condenser includes float valve and sump, discharge elbow, and
the distribution piping weight.
3. For special tubes refer to the 19XR/XRV Computer Selection Pro-
gram.
4. All weights for standard 2-pass NIH (nozzle-in-head) design.
1
/
the
5. For "E" compressor, add 1054 lb (478 kg) steel weight and 283 lb
2
(128 kg) refrigerant weight for economizer assembly.
119
METRIC (SI)
MACHINE CHARGE
REFRIGERANT
WEIGHT (KG)
COOLER CONDENSER COOLER CONDENSER
345
362
376
329
347
362
392
411
427
374
394
411
640
381
699
381
747
381
736
381
719
381
726
431
793
431
849
431
839
431
820
431
475
514
551
455
493
530
542
587
637
518
563
612
772
380
823
380
875
380
852
380
835
380
875
429
933
429
992
429
972
429
953
429
629
674
721
606
649
697
717
769
824
691
741
795
WATER WEIGHT
(KG)
586
609
635
607
629
653
638
664
694
662
686
715
912
1010
982
1085
1038
1157
1057
1182
1074
1190
991
1104
1072
1189
1135
1272
1157
1300
1177
1310
884
951
1012
913
979
1042
960
1036
1106
992
1068
1140
1238
1352
1300
1427
1364
1502
1386
1578
1407
1658
1340
1470
1411
1556
1485
1643
1510
1638
1534
1820
1253
1328
1402
1285
1362
1435
1358
1444
1528
1394
1482
1565