Manual Setup - How to change the wiring configuration

Below you will find a step-by-step example on how to change wiring configuration to 3-
phase WYE IT (IT = Interrupted Terra = Interrupted Ground).
24-10
info@Fluke-Direct.ca
Energy Loss (available under Function key F4): menu to set the
13
parameters for the Energy Loss measurement. Parameters to be set are:
four different tariff rates, cable data (length in meters/feet, diameter in
square millimeter or acc. to AWG / American Wire Gauge). In
Automatic mode setup of cable data is not required: the Analyzer bases
cost calculations on the assumption of three percent copper loss in the
cable. Other losses are calculated in ratio to the copper loss.
Back (available under Function key F5).
14
SETUP
F4
ENTER
Fluke-Direct
The active configuration is indicated in text and
in a diagram behind Config.
Note that a setup parameter is highlighted. If
required use the up and down arrow keys to select
setup parameter Config.
The screen shows 4 wiring configurations; 3-
phase WYE IT configuration is not among them.
Press F2 to access a second screen with 4 other
configurations.