15 mm from the
finished wall surface.
Outlet Pipe
Building-in Shroud
Smooth Side Against Wall
Plate Seals
18. Install the outlet pipe (ensure that the
final shower head position is at a
suitable height for all users). Ensure the
outlet pipe will protrude 15mm from the
wall once the finishing coat of plaster
and tiles are completed.
19. Slide the compression nut and olive
over the outlet pipe.
20. Insert the outlet pipe fully into the
shower control and slide the olive and
compression nut into place.
21. Use a suitable spanner to tighten the
compression nut.
22. Turn on the water supplies and check
for any leaks.