Technical data

determined in accordance with EN 624 or Truma test conditions
Protection type / protection class
IP21 / class I
Type of gas
LPG (Liquefied Petroleum Gas – propane / butane)
Operating pressure
2.75 kPa (see type plate)
Water capacity
10 litres
Maximum working water pressure
500 kPa
P&T relief valve setting
500 kPa – 99 °C – 10 kW
Heating up time from approx. 15 °C to approx. 60 °C
Hot water system approx. 23 minutes
(measured according to EN 15033)
Heater + hot water system approx. 90 min.
Pump pressure
max. 280 kPa
System pressure
max. 450 kPa
Nominal input (Propane)
Combi 2 E (Australia):
6.9 MJ/h
Combi 4 E (Australia): 13.6 MJ/h
Thermal output
Electrical operation (240 V):
Mixed operation (gas and electrical):
Gas operation
Combi 2 E (Australia):
max. 1950 W
Combi 4 E (Australia):
max. 3900 W
Gas consumption (Propane)
Combi 2 E (Australia):
Combi 4 E (Australia):
130 – 260 g/h
Air delivery volume (free-blowing without hot-air pipe)
with 3 hot-air outlets max. 249 m³/h
with 4 hot-air outlets max. 287 m³/h
Current input at 12 V
Heater + hot water system
Short-term max. 5.6 A (average power consumption 1.1 A)
Heating up of hot water system: 0.4 A
Stand-by: 0.001 A
Current input at 240 V ~
4.1 A (980 W) or 8.1 A (1960 W)
Weight (not containing water)
Heater unit:
16.2 kg
Heater unit with
peripheral devices: 16.8 kg
Water pressure reducer
Flow range water: 0 – 10 litres/min.
Maximum inlet pressure:
Maximum outlet pressure: 200 kPa
Dimensions
450 mm
Fig. 8
The right to make technical modifications is reserved!
980 W / 1960 W
max. 3900 W
130 g/h
700 kPa
510 mm

Accessories

Truma CP plus
Digital control panel Truma CP plus with automatic air condi-
tioning system for the iNet-capable Truma heaters Combi and
Truma air conditioning systems Aventa eco, Aventa comfort
(from serial number 24084022 – 04/2013), Saphir comfort RC
and Saphir compact (from serial number 23091001 – 04/2012)
– The automatic air conditio-
ning system function auto-
matically controls the heat-
er and the air conditioning
system until the required
temperature is reached in
the vehicle.
– With the Truma iNet Box
extension, all TIN-Bus-
capable Truma devices
can also be controlled
via the Truma App.
Truma iNet Box
The Truma iNet Box for simple networking and control of
Truma devices with a smartphone or tablet computer using
the app.
– Simple installation and
start-up via the Truma App
– Can be extended with the
update function, which
ensures that it is always up
to date.
Accessories (without picture) for control panels
– Cable available in different lengths
Fig. 9