– Guarantee claims, warranty claims and ac-
ceptance of liability will be ruled out in the
event of the following:
– modifications to the unit (including
accessories),
– modifications to the exhaust duct and the
cowl,
– failure to use original Truma parts as re-
placement parts and accessories,
– failure to follow the installation and operat-
ing instructions.
– It also becomes illegal to use the appliance,
and in some countries this even makes it il-
legal to use the vehicle.
– With a new Combi or if the unit has not been
used for some time, rinse all hot/cold water
hoses with drinking water thoroughly before
use.

Function description

The Combi 2 E / 4 E (Australia) liquefied gas heater is a warm-
air heater with integrated hot water system (10 litre capacity).
The burner is fan-assisted, which ensures that operation is
problem-free, even when on the move. The unit also has heat-
ing elements for electrical operation.
In heating and hot water mode the heater can be used to
heat the room and heat water at the same time. If only hot
water is required, select hot water mode.
3 different options are available for operating the unit:
– gas mode only
LPG for autonomous use
– electrical mode only
240 V for stationary use on camp sites
– or gas and electrical mode – mixed mode
Only possible in heating and hot water mode.
Heating and hot water mode
In heating and hot water mode, the unit automatically
selects the required operating level according to the tempera-
ture difference between the temperature set on the control
panel and the current room temperature. If the hot water sys-
tem has been filled, the water is automatically heated as well.
The water temperature depends on the selected operating
mode and the heater output.
All 3 energy selection options can be used for winter
deployment.
– In gas mode the unit automatically selects the operating
level that is required.
– In electrical mode output of 980 W (4.1 A) or 1960 W (8.1 A)
can be manually preselected in accordance with the fuse pro-
tection at the camp site.
If more output is required (e.g. heating up or low outside
temperatures) gas or mixed mode should be selected so
that enough heating power is always available.
– In mixed mode 240 V electrical mode is preferred if the
power requirement is low (e.g. for maintaining the room
temperature). The gas burner is not enabled until the power
requirement is higher, and is the first to switch off during
heat-up operation.
Hot water mode
(with filled hot water system only)
Gas mode or 240 V electrical mode is used to generate hot
water. The water temperature can be set to 60 °C.
– In gas mode the water is heated at the lowest burner
setting. Once the water temperature has been reached,
the burner switches off.
– In electrical mode output of 980 W (4.1 A) or 1960 W (8.1 A)
can be manually selected in accordance with the fuse protec-
tion at the camp site.
Mixed mode is not possible. With this setting the unit
automatically selects electrical mode. The gas burner is
not enabled.