    Fuel at low temperatures ............5 Intended use Operating instructions The Combi D 4 diesel heater is a warm air heater with inte‑ grated hot water boiler (10 litre volume). This unit was de‑ Control panels ..............5 signed for installation in motor homes and caravans. Instal‑...
  • Page 3: Safety Instructions

    / or second battery. – The unit may be operated only with appropri‑ Obligations of the operator / vehicle owner ate Truma control panels and accessories. – The operator is responsible for the water – Danger of toxic exhaust fumes. The heater’s with which the unit’s boiler is filled and for...
  • Page 4 – Use of replacement and accessory parts spected regularly, particularly following long other than original Truma parts, journeys, to check for any damage and to – Failure to follow the installation and ensure that the connection is sound. The operating instructions.
  • Page 5: Function Description

    Function description Operating instructions The Combi D 4 diesel heater is a warm air heater with an integrated hot water boiler (10 litre volume). The burner is fan‑ Read the safety instructions and operating instructions assisted, which ensures that operation is problem‑free, even when on the move.
  • Page 6: Opening The Safety/Drain Valve

    (position b) and the boiler filled. No claims may be made under the warranty for damage caused by frost. Truma supplies a heating element (part no. 70070‑01) as an accessory, which is plugged into the FrostControl and fixed in Initial start-up place with a retaining bracket.
  • Page 7: Maintenance

    Maintenance Technical data Only original Truma parts may be used for maintenance and Determined in accordance with Truma test conditions repair work. Fuel – Even out of season, the heater should be operated once a Diesel as per EN 590 Water capacity month for about 10 minutes.
  • Page 8: Faults

    “Troubleshooting guide (water supply)”. Accessories Troubleshooting guide (water supply) Truma CP plus Digital control panel Truma CP plus with automatic air con‑ ditioning system for the iNet‑capable Truma heaters Combi and Fault Cause / Remedy Truma air conditioning systems Aventa eco, Aventa comfort Water taking an extremely Water container furred. /...
  • Page 9: Manufacturer's Warranty (European Union)

    The warranty must be claimed with an authorised service part‑ ner or at the Truma Service Centre. All the relevant addresses This Warranty is applicable in EU member states as well as in and phone numbers can be found at www.truma.com, in the Iceland, Norway, Switzerland and Turkey.
  • Page 10 Should problems occur, please contact the Truma Service Centre or one of our authorised service partners (see www.truma. com). In order to avoid delays, please have the unit model and serial number ready (see type plate). Truma Gerätetechnik GmbH & Co. KG Service Wernher‑von‑Braun‑Straße 12...