Truma Combi D 6 AU Installation Instructions Manual

Truma Combi D 6 AU Installation Instructions Manual

Diesel heater
Hide thumbs Also See for Combi D 6 AU:

Advertisement

Truma Combi® D 6 AU
Installation instructions
Page 2

Advertisement

Table of Contents
loading

Summary of Contents for Truma Combi D 6 AU

  • Page 1 Truma Combi® D 6 AU Installation instructions Page 2...
  • Page 2: Installation Example

    Truma Combi® D 6 (Australia) Fig. 1 Installation example 1 Control panel 2 Room temperature sensor 3 Circulated air intake (min.150 cm²) 4 Warm air ducts 5 Warm air outlets 6 Wall cowl...
  • Page 3: Table Of Contents

    – modifications to the unit (including accessories), – modifications to the exhaust duct and the cowl, – failure to use original Truma parts as replacement parts and accessories, – failure to follow the installation and operating instructions.
  • Page 4: Choice Of Location

    Choice of location There must not be any heat-sensitive materials beneath the unit (e.g. flooring such as PVC or similar, cables etc.), since The unit and its exhaust duct must always be installed so that high temperatures can occur at the base of the unit. they are easy to access at all times for service work (e.g.
  • Page 5: Exhaust And Combustion Air Ducting

    Fit outer part of cowl Fill groove on outer part of cowl (8) with plastic body sealant Only Truma duct sets (consisting of an exhaust muffler, an (not silicone), then secure outer part of cowl to wall of vehicle extraction air duct and an air intake muffler) must be used for with 4 screws.
  • Page 6: Recirculated Air Intake

    Always connect gas-tight adapter (18) of exhaust muffler (4) Fit air intake muffler to unit to unit. Replace damaged O-ring (13). Route air intake muffler so that electrical connections – Slide clamp (22) onto extraction duct (5). remain accessible. – Slide adapter (18) of exhaust muffler (4) into muff (19) at unit as far as it will go.
  • Page 7: Warm Air Distribution

    The 4 muffs on the unit are designed for the 65 mm diameter ÜR duct (part no. 40230-00). Use only pressure-safe ducts in compliance with Truma quality requirements. Other ducts Always cut fuel hoses and lines to length using a sharp knife.
  • Page 8: Installing The Metering Pump

    Installing the metering pump Connect unit and metering pump to fuel pipe Mark hole for leading through fuel pipe (in soundproofing Always install metering pump with the pressure side (delivery hose) and metering pump connecting cable on floor of vehicle direction) sloping upwards.
  • Page 9: Water Connection

    A water hose may only be fitted at a clearance of 1.5 m to the heater on the warm air duct. The Truma hose clip SC (part no. 40712-01) can be used if this distance is observed. In the case of parallel installations, e.g.
  • Page 10: Installation Of The Pressure Reducer

    Installation of the pressure reducer Push the venting hose, external diameter 11 mm (47), onto the hose grommet of the venting valve (46a), and lay it to the Depending on the scope of supply – pressure reducer A or B outside without any kinks.
  • Page 11: Electrical Connections

    Electrical connections The connecting cables and plugs must not be subjected to force. Bundle connecting cables (see figure) and secure each Route connecting cables in such a way that they cannot one to housing using a cable binder in order to provide strain chafe.
  • Page 12: Control Panel / Air Conditioning System

    After a total of 15 unsuccessful starting attempts (initial and repeat start) without forming a flame, the equipment is blocked. To remove the block, please contact the Dometic Service Centre (see www.truma.com). Check fuel lines and connections for leaks after filling the fuel lines.
  • Page 16 In Australia, always notify the Dometic Service Centre if problems are encountered; in other countries the relevant service partners should be contacted (www.truma.com). Having the equipment model and the serial number ready (see type plate) will speed up processing. Dometic Pty Ltd...

Table of Contents