PROMPT
010 Force Arming?
1 = YES
0 = NO
0
010 Vent zone ?
1 = YES
0 = NO
0
010 Vent Re-arm ?
1 = YES
0 = NO
1
010 STAY MODE
None
0
010 Auto-stay ?
1 = YES
0 = NO
0
010 Silent ?
1 = YES
0 = NO
1
010 Bypass Group
01-15
01
EXPLANATION
If you entered 1 (YES) at the previous prompt, this prompt appears.
Enter 1 = to enable the system to automatically bypass the zone if it is faulted at the end of the exit
delay.
Enter 0 = Disable and the zone is faulted at the end of exit delay, the system either performs the exit
error logic, if field 1∗20 is enabled, or an alarm occurs.
UL
FORCE ARMING CANNOT BE ENABLED FOR UL INSTALLATIONS.
Press [∗] to continue.
.
If you selected response type 3, this prompt appears.
Enter 1 = Enable the arming of the partition with this zone faulted (force arm). The zone is
automatically bypassed.
Enter 0 = Disable.
NOTE: The zone may be unbypassed simply by restoring the zone (e. g., closing the window), if the
Vent Re-arm option (next prompt) for the zone is enabled.
Press [∗] to continue.
If you entered 1 (YES) at the previous prompt, this prompt will appear.
Enter 1 = to enable the system to automatically unbypass the zone when it is restored (e.g., by closing
the window).
Enter 0 = Disable. The zone is bypassed for the duration of the armed period regardless of the zone
status.
Press [∗] to continue.
If you selected response type 1, 2, 3, 4, 5, or 10, this prompt will appear.
Enter the STAY mode for this zone (0-2) and enter one of the following options:
0 = None: The zone is not bypassed when the partition is armed STAY.
NOTE: Cannot be selected for response types 4 and 10.
1 = Stay 1: The zone is automatically bypassed when the user enters [User Code] + [3] (STAY) + [1].
2 = Stay 2: The zone is automatically bypassed when the user enters [User Code] + [3] (STAY) + [2].
NOTES:
• Response types 4 and 10 are defaulted for STAY mode 1.
• If the user enters [User Code] + [3] (STAY) + [3], all zones assigned to Stay mode 1 and 2 in
the partition are automatically bypassed.
• If none of the zones in the partition are assigned to Stay mode 2, then when the user enters
[User Code] + [3] (STAY), all zones assigned to Stay mode 1 are automatically bypassed.
Press [∗] to continue.
If you selected response type 1, 2, 3, 4, 5, or 10, this prompt will appear.
Enter 1 = The zone is automatically bypassed if none of the entry/exit zones are opened during the
exit delay time (no one exits the premises).
Enter 0 = Disable.
NOTES:
• All zones enabled for auto-stay (except types 3 and 5), have an exit delay time when the
partition is armed.
• If auto-stay is enabled, make sure at least one zone is programmed for entry/exit in the
same partition otherwise this zone will be automatically bypassed every time the partition
is armed.
Press [∗] to continue.
If you selected response type 1, 2, 3, 4, 5, or 10, this prompt will appear.
Enter 1 = The zone follows all the selected response type's characteristics, except in the alarm
condition, the alarm output and the keypad sounder do not sound and the keypad does not
display the alarm condition.
Enter 0 = Disable.
Press [∗] to continue.
If you selected response type 1, 2, 3, 4, 5, or 10, this prompt will appear.
Enter the bypass group for the zone (01–15). This enables the user to bypass a group of zones by
entering [User Code] + [6] (Bypass) + [∗] + [Group No.] (01-15).
Enter 00 for None.
Press [∗] to continue.