You can program a user-friendly English language description/location for all protection zones, relays, keypad panics,
polling loop short, and RF receiver supervision troubles.
Each description can be composed of a combination of words (up to three) that are selected from a vocabulary of 253
words stored in memory, and any word can have an "s" or " 's " added to it.
NOTE: Due to the use of 3-digit zone numbers, the first word of the descriptor is limited to six characters if you want it to
fit on the top line of the display.
In addition, up to 60 installer-defined words can be added to those already in memory. Thus, when an alarm or trouble
occurs in a zone, an appropriate description for the location of that zone will be displayed at the keypad.
A custom installer's message can be programmed for each partition which is displayed when the system is "Ready" (e.g.,
HONEYWELL).
1. To program alpha descriptors, enter Programming mode, then press #93 to display "ZONE PROG?"
2. Press [0] (NO) three times to display "ALPHA PROG?"
3. Press [1] to enter Alpha Programming
There are six submenu selections that will be displayed one at a time.
Press [1] to select the mode desired.
Press [0] to display the next mode available. The alpha menu selections are:
Zone Descrip?
Default Screen? For creating custom message; displayed when system is ready.
Custom Word?
Part Descrip?
Exit Edit Mode? Press [1] to exit back to #93 Menu Mode.
4. Refer to the sections that follow for procedures for adding alpha descriptors.
Z
Z
o
o
n
n
e
e
D
D
e
e
s
s
c
c
r
r
i
i
p
p
t
t
o
o
r
r
s
s
PROMPT
ALPHA PROG.
?
1 = YES
0 = NO
Zone Descrip.
?
1 = YES
0 = NO 0
∗ ZN ???
(000=QUIT)
∗ ZN 001
A
∗ ZN 001
FAMILY
ROOM DOOR
P
r
o
g
r
a
m
m
i
n
g
P
r
o
g
r
a
m
m
i
n
g
For entering zone descriptors.
For creating custom words for use in descriptors.
For creating 4-character partition names.
EXPLANATION
To enter System Group #4 codes, press [1] (YES).
Enter 1 to program zone descriptors.
[3]
Scrolls both alphabet and actual words in ascending alphabetical order; then numerical order
0-9.
[1]
Scrolls both alphabet and actual words in descending alphabetical order; then numerical order
9-0.
[2]
Adds or removes an "s" or " 's " to a vocabulary word. Press [2] once to program an "s", press [2]
a second time to program an " 's".
[6]
Switches between alphabet and actual word list; used to accept entries.
[8]
Saves the entire zone description in the system's memory.
[#] [#] plus zone number reviews the current description for that zone.
Enter the THREE digit zone number.
Or
Enter [#] to view the zone descriptor.
CAUTION: pressing ∗ plus zone number will erase the current descriptor.
The keypad display the first letter on the top row keys perform the following functions:
NOTE: That the first letter of the alphabet appears after the zone number, and that the zone number is
automatically included with the description.
Enter [#] + the three digit word found in the "Alpha Descriptor Vocabulary".
For example: The descriptor we want for the zone 001 is "Family Room Door".
1. Press #079, FAMILY displays.
NOTE: The top line supports an eight character word.
2. Press [6] to move the cursor to the bottom line.
NOTE: The bottom line supports a maximum of 16 characters.
3. Press #169, ROOM displays.
4. Press [6] to move the cursor to the next word on the bottom line.
5. Press #061, Door displays.
6. Press [8] to save the word and return to the "Zone Entry Screen". Press ∗000 to quit, or the next
zone to start the process over.