Honeywell VISTA-128BPT Programming Manual page 29

Burglary partitioned security system
Hide thumbs Also See for VISTA-128BPT:
Table of Contents

Advertisement

FIELD
TITLE and DATA ENTRIES
∗90
Secondary Subscriber Account Number (partition-
specific)
Enter 00-09; B-F (11-15)
Enter a 4- or 10-digit (depending on report format in ∗47) secondary subscriber account number. Each number requires a
2-digit entry so as to allow entry of hexadecimal digits (B-F). If a 4-digit account number is to be used, enter data only in
the first four locations, and enter ∗ in the fifth location. Example: 4-digit account # 1234 would be 01 02 03 04 ∗.
NOTE: This field must be programmed if a secondary phone number is used (field ∗34). This account number can be the
same as the primary account number.
Check or TRBL Display
1∗07
0 = CHECK
1 = TRBL
Select whether the system should display TRBL or CHECK for trouble conditions.
Zone Bypass After Disarm
1∗11
0 = disable
1 = enable
Disabled: The USER CODE + OFF will not unbypass zones.
Enabled: The USER CODE + OFF will unbypass zones.
Unbypassing Process:
• To unbypass ALL zones, enter USER CODE + # + 64.
• To unbypass zones INDIVIDUALLY, you must enter USER CODE + 6 + zone number.
NOTES:
Automatically bypassed zones unbypass upon disarming of the control (e.g., STAY mode, Auto-STAY, etc.).
Vent zones and zones bypassed by a programmed Auto-Bypass schedule (Timed Driven Event) are considered
"manual bypasses" and will not be unbypassed upon disarming the system.
Zones that were in a bypassed state at the time a System Shutdown is sent from the Compass Downloading
software will be unbypassed when the System Shutdown is removed.
Cancel Verify
1∗15
0 = disable
1 = enable alarm output pulse upon kissoff of Cancel report.
Enabled: The bell output will pulse the alarm output 3 times and displays "Cancel report sent to central station" when the
panel receives a kissoff from central station for the cancel report.
NOTE: 1∗52 must be enabled to send a Cancel report to the central station.
NOTE: This feature is enabled by default, as is the cancel report code, for SIA compliance.
Lobby Partition
1∗17
0 = none
1-8 = partition number
Select the Common Lobby Partition.
NOTE: The Lobby partition must be the highest partition enabled in the panel, for instance if you have 3 partitions
enabled, partition 3 should be your common lobby partition.
Affects Lobby (partition-specific)
1∗18
0 = disable
1 = enable
If enabled, causes lobby partition to disarm when this partition disarms.
NOTE: This partition must be armed before lobby can be armed.
Arms Lobby (partition-specific)
1∗19
0 = disable
1 = enable
If enabled, arming this partition causes the system to attempt to arm the lobby partition automatically. To enable this field,
field 1∗18 must also be enabled (partition-specific).
NOTES:
• The lobby cannot be armed unless all partitions programmed for "affect" (field 1∗18) is already armed.
• If his field is enabled, Field 1∗18 for this partition must also be enabled.
SECTION 3: DATA FIELD DESCRIPTIONS
Default Values
[Blank]
|
A
E
A
A
|
A
E
[0]
E
A
[00000000]
A
1
E
[1]
E
A
[0]
E
A
[0]
E
A
[0]
E
A
25
|
|
|
|
|
E
A
A
E
A
A
E
A A
E
A
A
A A
A A
A A
A A
A A
A A
A A
2
3
4
5
6
7
E
E
E
E
E
E
E
E
E
E
E
E
E
|
E
A
A
E
A
8
E
E

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vista-250bptVista-128bptsia

Table of Contents