FIELD
TITLE and DATA ENTRIES
AC 60Hz/50Hz
1∗56
0 = 60Hz
1 = 50Hz
Select the frequency for the AC.
Must be set to 0 for U.S. and Canadian installations.
UL/UL
C
Enable 5800 RF Button Global Arm
1∗57
0 = disable
1 = enable
If enabled, the system arms/disarms in accordance with the button's user's global arming settings. See 1∗58.
1∗58
Enable 5800 RF Button Force Arm
0 = disable
1 = enable
If enabled, allows the RF button user to force a bypass of all faulted zones when arming the system.
NOTE: When attempting to arm the system, the keypad beeps once after the button is pressed if any faulted zones are
present.
ULC
FORCE ARMING IS NOT A ULC LISTED FEATURE AND MUST BE DISABLED FOR ULC INSTALLATIONS.
Zone 5 Audio Alarm Verification
1∗60
0 = disable
1 = enable
If enabled, zone 5 is used for 2-way audio (AAV).
NOTE: Zone 5 cannot be used as protection zone.
UL
MUST BE 0 FOR UL INSTALLATIONS.
Event Log Types
1∗70
0 = disable
1 = enable
Enabled: The system logs those events into the event log.
12/24 Hour Type Stamp Format
1∗71
0 = 12-hour
1 = 24-hour
Select the type of time stamping for the event log.
Event Log Printer On-Line Mode
1∗72
0 = disable
1 = enable
Enabled: The system prints the events as they occur.
Disabled: The system prints the log only upon request.
Relay Timeout XXX Minutes
1∗74
Enter 000-127 times 2 minutes (000-254).
This is used for #80 Menu Mode Time-Driven event relay command numbers "04/09" and Output Programming in the
#93 Menu Mode Programming output command "56."
Relay Timeout YYY Seconds
1∗75
Enter 000-127 seconds.
This is used for #80 Menu Mode Time-Driven event relay command numbers "05/10" and Output Programming in the
#93 Menu Mode Programming command "57."
Access Control Relay (partition-specific)
1∗76
01-96 = relay number
00 = relay not used.
If enabled, the assigned relay closes for 2 seconds when the user enters his code and presses 0.
UL
MUST BE 00 FOR UL INSTALLATIONS.
MUST BE A 0 FOR US (UL) AND CANADIAN (ULC) INSTALLATIONS.
SECTION 3: DATA FIELD DESCRIPTIONS
Default Values
[0]
E
A
[0]
E
A
[0]
E
A
[0]
E
A
[11111]
A
A
A
A larm
C hk
E
E
E
[0]
E
A
[0]
E
A
[000]
| |
A
E
[000]
| |
A
E
[00]
|
A
E
31
A
A
A
A
A
A
B yp
O /C
S yst
E
E
E
E
E
E
E