VISTA-128BPT/128BPT-SIA/250BPT PROGRAMMING GUIDE
FIELD TITLE and DATA ENTRIES
∗80
Zone Type Restores for Zone Types 9, 10, 14, 16
0 = disable
1 = enable
Enabled: Provides reporting for individual ZONE TYPES (not zone numbers).
∗83
First Test Report Time
Enter 00-07 for the day (01 = Monday)
Enter 00-23 for the hour
Enter 00-59 for the minutes
Enter the day and time that the first Test report shall be transmitted. Enter 00 in all locations if the Test report is to be sent
immediately upon exiting (see below). Enter 00 in the day location if the report is to be sent at the next occurrence of the
time that is set.
00,00,00 = Instant -Test will be sent right away when panel is reset (power up, Exit program mode, Download All from
∗84
Swinger Suppression (partition-specific)
Enter 01-14.
Enter 00 for unlimited reports
Enter the number of alarms to be sent to central station, per burglary zone, per armed period. Valid entries are 00-15. Fire
and Panic zones are not affected.
UL
MUST BE 00 FOR UL INSTALLATIONS.
∗85
Enable Dialer Reports for Panics & Duress (partition-
specific)
0 = disable
1 = enable
Program Zone 995, 996, 999, Duress Enable for each partition that the panics and duress reporting is desired.
NOTE: Non-zero report code must be assigned to zone 992 (duress) to enable Duress reporting.
If you enable any of the panics to report, programming location ∗22 must programmed correctly for each partition.
∗88
Abort Window (partition-specific)
0 = no delay
1 = 30-second delay
Enter [1] for 30 second delay on burglary alarm communication; otherwise [0] for no delay.
If delay is enabled and an alarm occurs, if you disarm before the delay time has expired the display will show 'ALARM
ABORTED' and the alarm report will not be sent. Applies to both communication paths, dialer and an AlarmNet ECP
communicator.
NOTE: Required for SIA.
UL
MUST BE 0 FOR UL INSTALLATIONS.
∗89
Restore Report Timing
0 = instant
1 = after bell timeout
2 = when system is disarmed
Option 0 = All Burg zone types have true zone restore while armed or disarmed. If a burg zone is not restored upon disarm,
the restore is sent anyway.
Option 1 = Restore is sent at bell timeout if the zone is restored, if not it is sent at disarm.
Option 2 = Restore is sent at disarm whether the zone is restored or not.
NOTE: This field only applies to Burglary Zone Types, it does not apply to Fire or Panic. See Restore Document for detailed
information on non-burg zone types and Restore reporting.
UL
Must be 2 for UL installations.
Compass [not when downloading System (user codes), or uploading, or setting clock]
Default Values
[0000]
A
A A
9
1 0
E
E
E
E
[00, 12, 00]
|
A
[01]
E
E
A
[0000]
A
A A
A A
9 95
9 96
9 99
E
E
E
E
E
[0]
E
A
[1]
E
A
24
A A
A A
1 4
1 6
E
E
E
E
|
|
E
A A
E
A A
E
A A
D uress
E
E
E