Section 4 • Repair Procedures
800-610-4101
ActionRental.com
Ground Controls
TMZ-34 models manufactured in the 1998 and
1999 model years (from serial number T3498-001
to T3499-769) were originally equipped with
ground controls boxes containing three printed
circuit boards. Machine functions are activated
using push buttons on the exterior of the box.
Beginning with the 2000 model year (from serial
number T3400-001 to date), the ground control box
was changed to a two-board configuration. The
push buttons used to activate machine functions
on earlier models were replaced with a membrane
overlay decal, mounted on the exterior of the box.
f
From serial number T3498-001 to T3499-769
a
b
c
d
e
f
4 - 20
a
c
b
D7
VOLTAGE
REGULATOR
N.O.
P1
N.C.
EMERGENCY
N.O.
STOP
e
d
voltage regulator D7
CPU circuit board U17
connector circuit board U21
key switch KS1
Emergency Stop button P2
key pad circuit board U15
a
SW25A
DIP SWITCH
P1
KS1
EMERGENCY
KEY
STOP
SWITCH
g
TMZ-34/19
June 2005
c
b
SW25
DIP SWITCH
D7
VOLTAGE
REGULATOR
e
f
d
From serial number T3400-001 to date
a
DIP switch SW25A
b
DIP switch SW25
c
connector circuit board U21
d
key switch KS1
e
CPU/display circuit board U22
f
voltage regulator D7
g
Emergency Stop button P2
Part No. 52075
REV C
KS1
KEY
SWITCH
Need help?